Description
The DT82E Environmental Data Logger
The new DT82E Environmental Data Logger Series 4 version has increased sampling speed, measurement range, and programmable analog output.
$1,820.00
In Stock
The new DT82E Environmental Data Logger Series 4 version has increased sampling speed, measurement range, and programmable analog output.
Analog Channels | |
---|---|
Analog Channels | 2 analog input channels Each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs 2 Wire w/ Com. Ref. Terminal: 6 Channels 2 Wire Isolated: 4 Channels 3 or 4 Wire Isolated: 2 Channels |
Fundamental Input Ranges | The fundamental inputs that the DT82E can measure are voltage, current, resistance and frequency. All other measurements are derived from these. |
Sampling | Integrates over 50/60 Hz Line Period for Accuracy and Noise Rejection Maximum Sample Speed: 40 Hz Effective Resolution: 18 Bits Linearity: 0.01% Common Mode Rejection: >90dB Line Series Mode Rejection: > 35dB |
Inputs | Inter-channel Isolation: 100V (relay switching) Analog Section Isolation: 100V (opto-isolated) Input impedence: 160KΩ, >100MΩ Current mode range: ±3.5V or ±55V (attenuator on/off) |
Sensor Excitation (Supply) | Analog Channels: Selectable 2µA, 213µA or 2.5mA Precision Current Source 4.5V Voltage Source or Switched External Supply General Purpose: Switchable 12V/5V Regulated Supply for Powering Sensors & Accessories (Max. 150mA) |
Analog Output | Isolated programmable 16-bit DAC: voltage 0-10V or current 0-24mA |
Analog Sensors | |
---|---|
Thermocouples | Type: B, C, D, E, G, J, K, N, R S, T Calibration Standard: ITS-90 |
RTDs | Materials Supported: Pt, Ni, Cu Resistance Range: 10Ω to 1MΩ |
Thermistors | Type: YSI 400xx Series, other Types* Resistance Range: Up to 1MΩ * Other Thermistor Types are Supported by Thermistor Scaling and Calculated Channels |
Monolithic Temperature Sensors | Type: LM34 – 60, AD590, AD592, TMPxx, LM135, LM235, LM335 |
Strain Gauge and Bridge Sensors | Configurations: 1/4, 1/2 & Full Bridge Excitation: Voltage or Current |
4-20mA Current Loop | Internal 100Ω Shunt or External Shunt Resistor |
Digital Channels | |
---|---|
Digital Input/Outputs | 4 Bi-Directional Channels Digital Input Type: 4 Logic Level (Max. 20/30 Volts) Digital Output Type: 3 With Open Drain FET (Max. 30V, 100mA), 1 with Logic Output |
Relay Output | 1 Latching Relay, contacts (Max: 30Vdc, 1A) |
Counter Channels | |
---|---|
Low Speed Counters | 4 Counters Shared with Digital Inputs 32 Bit Size, 10 Hz Max Count Rate Low Speed Counters do not Function in Sleep Mode |
Dedicated Counter Channels | 4 High Speed Inputs 32 Bit Size, 100kHz Max Count Rate 2 Logic Level Inputs (Max ±30V) 2 Sensitive Inputs (10mV) for Magnetic Pick Ups (Max. ±10V) |
Serial Channels | |
---|---|
SDI-12 | 1 SDI-12 Inputs, Shared with Digital Channels — Each input can support multiple SDI-12 Sensors |
Generic Serial Sensor | Flexible Option for Logging From Wide Range of Smart Sensors and Data Streams
Available ports: Host RS232 Port* |
Calculated Channels | |
---|---|
General | Combine values from analog, digital and serial sensors using expressions involving variables and functions. |
Functions | Arithmetic, Trigonometric, Relational, Logical and Statistical |
Alarms | |
---|---|
Condition | High, Low or Within Range and Outside Range |
Delay | Optional Time Period for Alarm Response |
Actions | Set Digital Outputs, Transmit Message, Execute any DataTaker Command. |
Scheduling of Data Acquisition | |
---|---|
Number of schedules | 11 |
Schedule rates | 10ms to days |
Data Storage | |
Internal Data Storage | Capacity: 128mb = approx 10,000,000 data points |
Removable USB storage device | Type:compatible with USb 1.1 or USB 2.0 drivers, e.g. Flash drive Capacity: approx 90,000 data points per megabyte |
Communication Interfaces | |
---|---|
Ethernet Port | Interface: 10BasteT (10Mbps) Protocol: TCP/IP, Modbus (Master & Slave) |
Host RS232 Port | Speed: 300 to 115,200 Baud (57,600 Default) Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None Handshake Lines: DCD, DSR, DTR, RTS, CTS Modem Support: Auto-Answer and Dial Out Protocols: ASCII Command, TCP/IP (PPP), Serial Sensor, Modbus |
Network TCP/IP Services | |
---|---|
Network | Ethernet and/or Host RS232 (PPP) Communication Ports |
Command Interface | Access the ASCII command interface via TCP/IP |
Web Server | Access Current Data and Status from any Web Browser — Custom pages can be defined — Download Data in CSV Format — Command Interface Window — Define Mimic Displays |
Modbus Server(slave) | Access current data and status from any Modbus client (e.g. SCADA system) |
FTP Server | Access logged data from any FTP client or web browser |
FTP Client | Automatically upload logged data direct to an FTP server. |
System | |
---|---|
Display and Keypad | Type: LCD, 2 Line by 16 Characters, Backlight Functions: Channel Data, Alarms, System Status Keypad: 6 Keys for Scrolling and Function Execution Status LEDs: 4 (Sample, Disk, Attention, Power) |
Firmware Upgrade | Via: RS232, Ethernet, USB or USB disk. |
Real Time Clock | Normal resolution: 200µs Accuracy: ±1 min/year (0°C to 40°C), ±4 min/year (-40°C to 70°C) |
Power Supply | External Voltage Range: 10 to 30 Volts DC Internal battery: 6Vdc 1.2Ahr lead acid Peak Power: 12 W (12VDC 1A) |
Average power Consumption | Using 12Vdc external power source 1 Sec Sampling: 1350 mW 5 Sec Sampling: 500 mW 30 Sec Sampling: 135 mW 5 Min Sampling: 70 mW 1 Hr Sampling: 60 mW |
Physical Environment | |
---|---|
Construction | Powder Coated Steel & Anodized Aluminum |
Dimensions | 180 x 137 x 65mm |
Weight | 1.5kg (4kg shipping) |
Operating Range | Temperature: -45°C to 70°C (Reduced LCD Operation Outside Range: -15°C to 50°C) Humidity: 85% RH, Non-condensing |
Resources Included | |
---|---|
Resource CD | Includes software, video training and user manual |
Comms cable | USB cable |
Line adapter | 110/240Vac to 15 Vdc, 800mA |
dEX data logger software is an intuitive graphical interface that allows you to configure your data logger, view real-time data in mimics, trend charts or tables and retrieve your historical data for analysis.
dEX comes pre-installed on every logger in the DT80 range. The software loads in your web browser so there is no need to install cumbersome applications on your computer. Being browser-based, dEX will work on all major operating systems including Windows, Mac and Linux.
The configuration editor allows you to view, edit and save logger configurations in an easy-to-use Windows Explorer style user interface. The configuration tree view allows definition of measurement schedules and measurements.
Wiring diagrams show available wiring configurations for each sensor type. Configuration can be stored and retrieved on either the logger or a local computer.
Mimics are organized into panels which can be modified to highlight custom alarm conditions or data grouping. Mimics include dials, bar graphs, thermometers, etc. Real-time chart recorder mimic allows you to view trends and historical data over a custom time/date range. Up to 16 mimics can be displayed on up to 5 mimic pages.
• Web Browser – Internet Explorer (IE7 or later), Safari, Google Chrome, Firefox
• Adobe Flash Player (10 or higher)
• Screen resolution of 1024 x 768