<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>single phase Archives - CAS Dataloggers</title>
	<atom:link href="https://dataloggerinc.com/product-tag/single-phase/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/product-tag/single-phase/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Mon, 11 Aug 2025 20:07:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>single phase Archives - CAS Dataloggers</title>
	<link>https://dataloggerinc.com/product-tag/single-phase/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electrocorder EC-2VA</title>
		<link>https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-2va-single-phase-voltage-and-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>One voltage channel 300Vac, One current channel 300Aac</li>
<li>Enables voltage and load problems to be highlighted for further investigation.</li>
<li>One Voltage input (L1), one Current input (A1).</li>
<li>Voltage channels record VAvg, VMax &#38; VMin.</li>
<li>Recorded data is uploaded via USB to a PC for analysis with Free Electrosoft Software.</li>
<li>Data is stored in non-volatile memory.  Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording.</li>
<li>Kit includes Logger, voltage input lead, Rogowski Coil, USB lead, software and carry case.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Single Phase EC-2VA AC Voltage Current Logger</h3>
<p>The EC-2VA AC Voltage Current Data Logger is specifically designed to monitor one voltage channel and one current. It allows you to monitor the main voltage supply and the load current, enabling staff to determine whether a voltage problem is load-related or not.</p>
<p>The Electrocorder range is designed to allow electrical distribution companies to cost-effectively monitor single and three-phase supplies. Our products allow voltage problems to be highlighted quickly for further investigation. The EC-2VA is designed to allow engineering staff to monitor single-phase voltage and current.</p>
<p>The voltage and current levels are stored with dates and times. With the backup battery, the Electrocorder can continue to record for a year. On the logger, the recording is signified by a flashing green light. A red light advises users that the unit has completed recording.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-1V</title>
		<link>https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-1v-single-phase-voltage-logger/</guid>

					<description><![CDATA[<ul>
<li>Single Phase 300Vac (Live/Hot to Neutral)</li>
<li>Voltage recorder enables real voltage problems to be highlighted quickly for further investigation</li>
<li>Electrosoft includes an internal database to ensure effective management of distributed units</li>
<li>Selectable measurement resolution to suit each situation, accurate to ±1% of reading + 1 Volt (90 - 260Vac)</li>
<li>Small, safe &#38; easy to use</li>
<li>Records average voltage, max &#38; min with date &#38; time &#38; stores information in non-volatile memory</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, &#38; USB cable</li>
<li>Recorded data is uploaded to a PC for analysis with supplied free software</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/">Electrocorder EC-1V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Single Phase, Waterproof EC-1V AC Voltage Data Logger</h2>
<p>The EC-1V AC Voltage Data Logger is widely used to monitor voltage variations on site, allowing voltage problems to be highlighted quickly for further investigation using traditional recorders.</p>
<p>When recording the Electrocorder will store the average voltage over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.<img decoding="async" style="float: right; margin: 20px;" src="https://dataloggerinc.com/images/electrocorder/ec-1v_2.jpg" /></p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range uses a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period, and the Min, the lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/">Electrocorder EC-1V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-3A</title>
		<link>https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-3a-single-and-three-phase-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>Three phase selectable range; 400A, 1kA, 2kA or 3kAac</li>
<li>Enables current and load problems to be highlighted for further investigation</li>
<li>Allows users to record load currents up to 3kAac, range is model dependent</li>
<li>Three current input channels (A1, A2, &#38; A3)</li>
<li>Records Max, Min and Avg current on all 3 channels</li>
<li>Data stored in non-volatile memory</li>
<li>Recorded data is uploaded to a PC for analysis with Electrosoft</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, 3 Rogowski Transducers, USB lead &#38; 12Vdc PSU</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/">Electrocorder EC-3A</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>EC-3A AC Current Data Logger &#8211; Single &amp; Three Phase</h3>
<p>The EC-3A AC Current Data Logger is specifically designed to monitor one, two, or three current channels, allowing you to monitor the loading and energy consumption of the installation. The stored data is uploaded to a PC via the supplied USB cable.</p>
<p>The product is supplied with three Rogowski transducers. Four models are available. The EC-3A-FK has a range of 5 to 400A, the EC-3A-1K has a range of 10-1kA, the EC-3A-2K a range of 15-2kA, and the EC-3A-3K a range of 20-3kA. Other ranges may be factory set, normally up to around 10kA per phase.</p>
<p>When recording the Electrocorder will store the average current over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.</p>
<p>The current levels are stored with dates and times. With the backup battery, the Electrocorder can continue to record for 3 months. A 12Vdc PSU input is available, to allow for prolonged logging without battery power.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/">Electrocorder EC-3A</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>