<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Accsense Electrocorder Data Logger Products - CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/accsense-electrocorder/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/accsense-electrocorder/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Thu, 04 Jun 2026 12:12:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Accsense Electrocorder Data Logger Products - CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/accsense-electrocorder/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Electrocorder AL-2VA</title>
		<link>https://dataloggerinc.com/product/electrocorder-al-2va/</link>
					<comments>https://dataloggerinc.com/product/electrocorder-al-2va/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 02 Jul 2024 14:43:12 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=992894</guid>

					<description><![CDATA[<ul>
<li>One voltage channel 300Vac, One current channel up to 15Aac</li>
<li>Enables voltage and load problems to be highlighted for further investigation.</li>
<li>Voltage channels record VAvg, VMax &#38; VMin.</li>
<li>Recorded data is uploaded via USB to a PC for analysis with Free Electrosoft Software.</li>
<li>Data is stored in non-volatile memory.  Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording.</li>
<li>Kit includes logger, mains socket, USB lead, Electrosoft software, and carry case.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/electrocorder-al-2va/">Electrocorder AL-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>AL-2VA Single Phase Energy/Power Logger</h3>
<p>The AL-2VA is designed to allow users to monitor one voltage channel and one current channel. Allowing users to monitor the main voltage supply and the load current, therefore enabling staff to determine the energy consumption of various appliances or items of equipment.</p>
<p>Setting up the Electrocorder AL-2VA is easy, making it suitable for non-technical staff. Using the supplied (free) Windows software, Electrosoft; input the location details for the logging and choose the logging period. Electrosoft will print the necessary dispatch/ return documentation including user instructions. All data is included in a database of dispatches and returns, allowing you to track the location of multiple loggers.</p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range uses a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period, and the Min, the lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer. The voltage and current levels are stored with dates and times. With the backup battery, the logger can continue to record for months. On the logger, data recording is signified by a flashing green light. A red light advises users that the unit has completed recording.</p>
<p>When the logger has finished recording, the stored data is uploaded to a PC via the supplied USB cable. Using Electrosoft, the recorded voltage and current levels have dates and times that can be viewed in both tabular and graphical form, exported to a spreadsheet, or saved to a file. Graphs can be printed showing the recorded levels and the allowable tolerance bands. Electrosoft also provides an internal database that effectively manages the distribution of multiple loggers.</p>
<p>&nbsp;</p>
<p>The post <a href="https://dataloggerinc.com/product/electrocorder-al-2va/">Electrocorder AL-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/electrocorder-al-2va/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Electrocorder EC-2VA</title>
		<link>https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-2va-single-phase-voltage-and-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>One voltage channel 300Vac, One current channel 300Aac</li>
<li>Enables voltage and load problems to be highlighted for further investigation.</li>
<li>One Voltage input (L1), one Current input (A1).</li>
<li>Voltage channels record VAvg, VMax &#38; VMin.</li>
<li>Recorded data is uploaded via USB to a PC for analysis with Free Electrosoft Software.</li>
<li>Data is stored in non-volatile memory.  Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording.</li>
<li>Kit includes Logger, voltage input lead, Rogowski Coil, USB lead, software and carry case.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Single Phase EC-2VA AC Voltage Current Logger</h3>
<p>The EC-2VA AC Voltage Current Data Logger is specifically designed to monitor one voltage channel and one current. It allows you to monitor the main voltage supply and the load current, enabling staff to determine whether a voltage problem is load-related or not.</p>
<p>The Electrocorder range is designed to allow electrical distribution companies to cost-effectively monitor single and three-phase supplies. Our products allow voltage problems to be highlighted quickly for further investigation. The EC-2VA is designed to allow engineering staff to monitor single-phase voltage and current.</p>
<p>The voltage and current levels are stored with dates and times. With the backup battery, the Electrocorder can continue to record for a year. On the logger, the recording is signified by a flashing green light. A red light advises users that the unit has completed recording.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-7VAR</title>
		<link>https://dataloggerinc.com/product/ec-7var-power-energy-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-7var-three-phase-voltage-current-logger/</guid>

					<description><![CDATA[<ul>
<li>Records voltage, current, power factor, power and energy</li>
<li>Three voltage input channels (L1, L2, &#38; L3), 0-600V &#38; Neutral(N) 0-300V</li>
<li>Voltage channels record VAvg, VMax &#38; VMin on all 3 channels. Data stored in non-volatile memory</li>
<li>Three current channels (A1, A2 &#38; A3) 400A or 3kA switch selectable</li>
<li>Three current channels record IAvg, IMax &#38; IMin on all 3 channels. Data stored in non-volatile memory</li>
<li>Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording</li>
<li>Kit includes logger, Rogowski transducers, voltage leads, USB lead, software &#38; carry case</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-7var-power-energy-data-logger/">Electrocorder EC-7VAR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The EC-7VAR Power Energy Data Logger is specifically designed to monitor one, two or three current channels, as well as one, two or three voltage channels. It allows you to monitor the loading and energy consumption of the installation. Power Factor recorded is the phase angle between L1 and A1. Amp ranges are selectable from 400 or 3000 AAC.</p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range use a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period and the Min, lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>The voltage and current levels are stored with dates and times. With the back-up battery, the Electrocorder can continue to record for months.</p>
<h3>Read More About the EC-7VAR Power Energy Data Logger:</h3>
<div class="woocommerce-product-details__short-description">
<p><a href="https://dataloggerinc.com/news-article/affordable-kit-monitors-power-factor/"> Is Uncorrected Power Factor Costing You Money?</a></p>
<p class="entry-title"><a href="https://dataloggerinc.com/news-article/affordable-kit-monitors-power-factor/">Energy Savings Kit Logs Power Factor and More</a></p>
<p class="entry-title"><a href="https://dataloggerinc.com/resource-article/measure-voltage-and-current-data-logger/">How to Record Accurate AC and DC Voltage and Current Measurements</a></p>
</div>
<p>The post <a href="https://dataloggerinc.com/product/ec-7var-power-energy-data-logger/">Electrocorder EC-7VAR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-1V</title>
		<link>https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-1v-single-phase-voltage-logger/</guid>

					<description><![CDATA[<ul>
<li>Single Phase 300Vac (Live/Hot to Neutral)</li>
<li>Voltage recorder enables real voltage problems to be highlighted quickly for further investigation</li>
<li>Electrosoft includes an internal database to ensure effective management of distributed units</li>
<li>Selectable measurement resolution to suit each situation, accurate to ±1% of reading + 1 Volt (90 - 260Vac)</li>
<li>Small, safe &#38; easy to use</li>
<li>Records average voltage, max &#38; min with date &#38; time &#38; stores information in non-volatile memory</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, &#38; USB cable</li>
<li>Recorded data is uploaded to a PC for analysis with supplied free software</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/">Electrocorder EC-1V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Single Phase, Waterproof EC-1V AC Voltage Data Logger</h2>
<p>The EC-1V AC Voltage Data Logger is widely used to monitor voltage variations on site, allowing voltage problems to be highlighted quickly for further investigation using traditional recorders.</p>
<p>When recording the Electrocorder will store the average voltage over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.<img decoding="async" style="float: right; margin: 20px;" src="https://dataloggerinc.com/images/electrocorder/ec-1v_2.jpg" /></p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range uses a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period, and the Min, the lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-1v-ac-voltage-data-logger/">Electrocorder EC-1V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-3V</title>
		<link>https://dataloggerinc.com/product/ec-3v-ac-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-3v-single-and-three-phase-voltage-logger/</guid>

					<description><![CDATA[<ul>
<li>Three phase; 600Vac (L1, L2 &#38; L3 to Neutral) with phase rotation checker</li>
<li>Enables voltage problems to be highlighted quickly for further investigation</li>
<li>Three phase input (L1, L2, &#38; L3) &#38; Neutral (N). Use for single phase logging also</li>
<li>Integral Phase Sequence or Rotation Checker</li>
<li>Kit includes Logger, Carry Case, Free Electrosoft software, input leads &#38; USB lead</li>
<li>Selectable averaging period to suit each situation, accurate to ±1% of reading, ±1 volt&#62;</li>
<li>Memory capacity of 32,000 true RMS voltage values per phase (10 bit), up to 300 days continuous recording</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-3v-ac-voltage-data-logger/">Electrocorder EC-3V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>EC-3V AC Voltage Data Logger with Integral Phase Sequence/Rotation Checker</h3>
<p>The EC-3V AC Voltage Data Logger allows engineers to quickly and cost-effectively monitor and resolve single &amp; 3-phase voltage problems. It has an integral Phase Sequence/Rotation Checker. The voltage levels are stored with dates and times. With the back-up battery, the Electrocorder data logger can continue to record for a year.</p>
<p>Kit includes data logger, voltage input leads, USB lead, Electrosoft software and carry case.</p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range use a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period and the Min, lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-3v-ac-voltage-data-logger/">Electrocorder EC-3V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-3A</title>
		<link>https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-3a-single-and-three-phase-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>Three phase selectable range; 400A, 1kA, 2kA or 3kAac</li>
<li>Enables current and load problems to be highlighted for further investigation</li>
<li>Allows users to record load currents up to 3kAac, range is model dependent</li>
<li>Three current input channels (A1, A2, &#38; A3)</li>
<li>Records Max, Min and Avg current on all 3 channels</li>
<li>Data stored in non-volatile memory</li>
<li>Recorded data is uploaded to a PC for analysis with Electrosoft</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, 3 Rogowski Transducers, USB lead &#38; 12Vdc PSU</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/">Electrocorder EC-3A</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>EC-3A AC Current Data Logger &#8211; Single &amp; Three Phase</h3>
<p>The EC-3A AC Current Data Logger is specifically designed to monitor one, two, or three current channels, allowing you to monitor the loading and energy consumption of the installation. The stored data is uploaded to a PC via the supplied USB cable.</p>
<p>The product is supplied with three Rogowski transducers. Four models are available. The EC-3A-FK has a range of 5 to 400A, the EC-3A-1K has a range of 10-1kA, the EC-3A-2K a range of 15-2kA, and the EC-3A-3K a range of 20-3kA. Other ranges may be factory set, normally up to around 10kA per phase.</p>
<p>When recording the Electrocorder will store the average current over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.</p>
<p>The current levels are stored with dates and times. With the backup battery, the Electrocorder can continue to record for 3 months. A 12Vdc PSU input is available, to allow for prolonged logging without battery power.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-3a-ac-current-data-logger/">Electrocorder EC-3A</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder PV-3</title>
		<link>https://dataloggerinc.com/product/pv-3-solar-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/pv-3-solar-data-logger/</guid>

					<description><![CDATA[<ul>
<li>Records Solar Irradiance, 0-1500W/m-2</li>
<li>PV system output Vdc to 300V, Idc to 100A</li>
<li>Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other applications</li>
<li>Accurately record DC voltages up to 60Vdc</li>
<li>Two voltage input channels and one current channel</li>
<li>Records VAvg, VMax &#38; VMin on 2 channels. Data is stored in non-volatile memory</li>
<li>Kit includes logger, fused voltage input leads, DC current probe, pyranometer, USB lead, 12Vdc PSU, software and carry case</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pv-3-solar-data-logger/">Electrocorder PV-3</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>PV-3 Solar Data Logger</h3>
<p>The PV-3 solar data logger is used by installers, householders, renewable energy companies to check PV (photo voltaic) installations. It can record solar irradiation up to 1,500W/m2 (watts per square metre), DC Voltage and DC Current produced by the panel, allowing you to assess the performance of a solar energy installation.</p>
<p>Why is the Electrocorder solar data logger better than other similarly priced competitors? The Electrocorder range use a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the TRMS average, the Max, which is the highest cycle value during the period and the Min, lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>When recording the Electrocorder will store the average voltage (and current if applied) over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.</p>
<p>The voltage levels are stored with dates and times. With the back-up battery, the Electrocorder can continue to record for 4 weeks. An external 12Vdc PSU input is available, to allow for prolonged logging without batteries. Memory capacity of 32,000 TRMS voltage values per channel (10 bit).</p>
<p>The post <a href="https://dataloggerinc.com/product/pv-3-solar-data-logger/">Electrocorder PV-3</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder DC-3VA</title>
		<link>https://dataloggerinc.com/product/dc-3va-dc-voltage-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:47 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/dc-3va-two-channel-dc-voltage-and-current-logger-kit/</guid>

					<description><![CDATA[<ul>
<li>2 Channels Voltage (300V), 1 Channel Current +/-10A or +/-100A</li>
<li>Records DC voltage and current</li>
<li>Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other application</li>
<li>Accurately record DC voltages and DC current</li>
<li>Records VAvg, VMax &#38; VMin on 2 channels, Iavg, Imax &#38; Imin on 1 channel</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, three fused voltage leads, DC current probe, USB lead &#38; 12Vdc PSU</li>
<li>Memory capacity of 32,000 true RMS values per channel (10 bit), up to 300 days continuous recording</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dc-3va-dc-voltage-current-data-logger/">Electrocorder DC-3VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Electrocorder DC-3VA DC Voltage Current Data Logger</h3>
<p>The DC-3VA DC Voltage Current Data Logger is a two-channel data logger specifically designed to accurately monitor one or two DC voltage channels, 1V to 300Vdc, and one DC current channel, allowing you to monitor PV (photovoltaic) cell output, DC charger performance, as well as many other applications &#8211; like DC motors. The stored data is uploaded to a PC via the supplied USB cable.</p>
<p>The kit includes a data logger, fused voltage leads, DC current probes, USB lead, 12Vdc PSU, Electrosoft software, and a carry case. IP65-rated enclosure.</p>
<p>When recording, the Electrocorder will store the average DC voltage and DC current over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) values during that period.</p>
<p>The advantage of Electrocorder products over most others is that our Data Loggers constantly sample information (recording the Minimum, Maximum, and Average reading) over the set period. Many other products only take ‘snapshots’ of what is going on and can miss 99.9% of the data that is critical to your analysis.</p>
<p>The post <a href="https://dataloggerinc.com/product/dc-3va-dc-voltage-current-data-logger/">Electrocorder DC-3VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
