<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>WattNode Electrical Meters &amp; Current Transformers - CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/data-logger-accessories/wattnode/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/data-logger-accessories/wattnode/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Thu, 10 Sep 2026 18:47:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>WattNode Electrical Meters &amp; Current Transformers - CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/data-logger-accessories/wattnode/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ACTL-1250 Split-Core Current Transformer</title>
		<link>https://dataloggerinc.com/product/accu-ct-actl-1250/</link>
					<comments>https://dataloggerinc.com/product/accu-ct-actl-1250/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 13 Aug 2019 14:41:53 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=30686</guid>

					<description><![CDATA[<ul>
<li>Split-core design for easy installation</li>
<li>1.25" x 1.83" Opening accommodates one 750 kcmil (MCM) or two 350 kcmil (MCM) conductors</li>
<li>0.333Vac output with 8' lead wires</li>
<li>UL2808 Listed for use up to 600Vac</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/accu-ct-actl-1250/">ACTL-1250 Split-Core Current Transformer</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Accu-CT ACTL-1250 split-core current transformer from <a href="https://ctlsys.com/" target="_blank" rel="noopener noreferrer">Continental Control Systems</a> offers outstanding linearity and very low phase angle error with easy one-handed opening and closing, even wearing gloves.</p>
<p>The standard Accu-CT meets IEEE C57.13 class 1.2.</p>
<p>✔ Excellent Linearity<br />
✔ Low Phase Angle Error<br />
✔ UL 2808 (XOBA) Listed<br />
✔ All CTs Are Not the Same!</p>
<p><strong>Square 0.75 in. Window Opening 5A to 250 A</strong></p>
<p>The patented Accu-CT ACTL-1250 split-core current transformer technology delivers exceptional linearity and low-end accuracy. Developed specifically for solar inverter, variable-speed motor drive, and other applications where there are large variations in current. The 100:1 turndown ratio of Accu-CTs is ten times better than industry standard CTs. The unique one-handed opening and closing mechanism make installation a snap.</p>
<ul>
<li>Safe: built-in burden resistor provides 0.333 Vac voltage output at the rated full-scale current—no shorting blocks needed!</li>
<li>UL 2808 Listed meets 2017 NEC code requirements for field-installed current transformers</li>
<li>IEEE C57.13 and IEC 60044-1 accuracy: over the full temperature range and down to below 1% of rated current</li>
<li>Exceptionally low phase angle error: essential for accurate power and energy measurements</li>
<li>Glove-friendly: easy to open and install with one hand while wearing safety gloves</li>
<li>Approvals: CE mark and RoHS compliant</li>
</ul>
<p>We also offer the <a href="https://dataloggerinc.com/product/wattnode-wnd-wr-mb/" target="_blank" rel="noopener noreferrer">WattNode WND-WR-MB Modbus Energy Meter</a></p>
<p>The post <a href="https://dataloggerinc.com/product/accu-ct-actl-1250/">ACTL-1250 Split-Core Current Transformer</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/accu-ct-actl-1250/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>ACTL-0750 Split-Core Current Transformer</title>
		<link>https://dataloggerinc.com/product/accu-ct-actl-0750/</link>
					<comments>https://dataloggerinc.com/product/accu-ct-actl-0750/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 13 Aug 2019 14:41:48 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=30657</guid>

					<description><![CDATA[<ul>
<li>Split-core design for easy installation</li>
<li>0.75" Square opening accommodates 4/0, 250 kcmil conductors</li>
<li>0.333Vac output with 8' lead wires</li>
<li>UL2808 Listed for use up to 600Vac</li>
</ul>
<p><strong> </strong></p>
<p>The post <a href="https://dataloggerinc.com/product/accu-ct-actl-0750/">ACTL-0750 Split-Core Current Transformer</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Accu-CT ACTL-0750 split-core current transformer from <a href="https://ctlsys.com/" target="_blank" rel="noopener noreferrer">Continental Control Systems</a> offers outstanding linearity and very low phase angle error with easy one-handed opening and closing, even wearing gloves.</p>
<p>The standard Accu-CT meets IEEE C57.13 class 1.2.</p>
<p>✔ Excellent Linearity<br />
✔ Low Phase Angle Error<br />
✔ UL 2808 (XOBA) Listed<br />
✔ All CTs Are Not the Same!</p>
<p><strong>Square 0.75 in. Window Opening 5A to 250 A</strong></p>
<p>The patented Accu-CT ACTL-0750 split-core current transformer technology delivers exceptional linearity and low-end accuracy. Developed specifically for solar inverter, variable-speed motor drive, and other applications where there are large variations in current. The 100:1 turndown ratio of Accu-CTs is ten times better than industry standard CTs. The unique one-handed opening and closing mechanism make installation a snap.</p>
<ul>
<li>Safe: built-in burden resistor provides 0.333 Vac voltage output at the rated full-scale current—no shorting blocks needed!</li>
<li>UL 2808 Listed meets 2017 NEC code requirements for field-installed current transformers</li>
<li>IEEE C57.13 and IEC 60044-1 accuracy: over the full temperature range and down to below 1% of rated current</li>
<li>Exceptionally low phase angle error: essential for accurate power and energy measurements</li>
<li>Glove-friendly: easy to open and install with one hand while wearing safety gloves</li>
<li>Approvals: CE mark and RoHS compliant</li>
</ul>
<p>We also offer the <a href="https://dataloggerinc.com/product/wattnode-wnd-wr-mb/" target="_blank" rel="noopener noreferrer">WattNode WND-WR-MB Modbus Energy Meter</a></p>
<p>The post <a href="https://dataloggerinc.com/product/accu-ct-actl-0750/">ACTL-0750 Split-Core Current Transformer</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/accu-ct-actl-0750/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>WattNode WND-WR-MB</title>
		<link>https://dataloggerinc.com/product/wattnode-wnd-wr-mb/</link>
					<comments>https://dataloggerinc.com/product/wattnode-wnd-wr-mb/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 13 Aug 2019 12:47:20 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=30404</guid>

					<description><![CDATA[<ul>
<li>100-600 Vac, wye and delta, single-phase and three-phase with a single model</li>
<li>Correct wiring errors remotely</li>
<li>Change a CT’s polarity</li>
<li>Change a CT to a different line voltage</li>
<li>SunSpec certified</li>
<li>Updates readings every 100 ms</li>
<li>Class 0.5 accuracy</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/wattnode-wnd-wr-mb/">WattNode WND-WR-MB</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The WattNode WND-WR-MB Wide-Range Modbus<sup>®</sup> energy meter from <a href="https://ctlsys.com/" target="_blank" rel="noopener noreferrer">Continental Control Systems</a> measures bi-directional energy (kWh), power (kW demand), voltage, current, power factor, and much more. It works on all electrical services from 100 to 600 Vac, single-phase or three-phase, wye or delta. It can be powered line-to-neutral or line-to-line and communicates with any of our data loggers that support the Modbus<sup>®</sup> RTU protocol which includes the dataTaker DT8x family, Delphin Expert family, and Infinite ADU systems.</p>
<p>The WattNode WND-WR-MB requires external Current Transformers with 0.333 Vac output voltage. Choose from one of the following or supply your own. Other models/ranges available on request.</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li><a href="https://dataloggerinc.com/product/accu-ct-actl-0750-100/" target="_blank" rel="noopener noreferrer">ACTL-0750-100</a>: 100 Amp Rated</li>
<li><a href="https://dataloggerinc.com/product/accu-ct-actl-1250-250/" target="_blank" rel="noopener noreferrer">ACTL-1250-250</a>: 250 Amp Rated</li>
<li><a href="https://dataloggerinc.com/product/accu-ct-actl-1250-400" target="_blank" rel="noopener noreferrer">ACTL-1250-400</a>: 400 Amp Rated</li>
</ul>
</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/wattnode-wnd-wr-mb/">WattNode WND-WR-MB</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/wattnode-wnd-wr-mb/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>