<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DC Voltage Current Data Loggers - CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/dc-voltage-current-data-loggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/dc-voltage-current-data-loggers/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Fri, 22 Aug 2025 20:36:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>DC Voltage Current Data Loggers - CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/dc-voltage-current-data-loggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Eltek GS-44</title>
		<link>https://dataloggerinc.com/product/gs-44/</link>
					<comments>https://dataloggerinc.com/product/gs-44/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 15 Jun 2018 14:39:11 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=17830</guid>

					<description><![CDATA[<ul>
<li>4 Voltage/Current inputs</li>
<li>Voltage measurement range 0-100mV to 0-10V</li>
<li>Current measurement range 0-20mA</li>
<li>Wireless communication range of up to 1000 meters (3000 feet)</li>
<li>LCD Display</li>
<li>Battery life up to 4 years</li>
<li><strong>Additional Receiver required for communication</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/gs-44/">Eltek GS-44</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The GS-44 Wireless Transmitter has 4 voltage/current inputs that can be configured to measure from 0-10V or 0-20 mA. It uses a 900 MHz wireless transmitter that provides communication range of up to 1000 meters in open air. The GS-44 is battery powered with a battery life of up to 4 years depending on transmission interval and environment.</p>
<p>The transmitter is compatible with all of the Eltek GenII receivers including the RX250AL receiver with alarm output, SC250 secure receiver, RC250 serial output receiver, WSR wireless sensor receiver and RP250GD wireless repeater. These systems utilize Elteks’ DARCA software for configuration, monitoring and data retrieval.</p>
<p>The post <a href="https://dataloggerinc.com/product/gs-44/">Eltek GS-44</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/gs-44/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AEMC Powerpad III 8333</title>
		<link>https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 30 Nov 2016 23:32:38 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=5825</guid>

					<description><![CDATA[<ul>
<li>Measures TRMS Voltage up to 1000 Vrms AC or 1200 VDC for 1, 2 and 3-phase Systems</li>
<li>Measures TRMS Current up to 10 kArms (Sensor Dependent)</li>
<li>(4) Voltage Inputs and (3) Current Inputs</li>
<li>VA, var, W, kVAh, VARh, kWh and Totals (per Phase) Measurements and Recordings</li>
<li>Stores Trend Data, 4,000 Alarms, 51 Captured Transients and up to 12 Screen Snap Shots</li>
<li>Measures Harmonics for Voltage, Current or Power up to the 50th Harmonic</li>
<li>CE, Shock Resistant and Classified: IEC61000-4-30 Class B, IP50, 1000 V CAT III and 600 V CAT IV</li>
<li>USB Communication Interface</li>
<li>LCD Display Shows Real-time Waveforms and Trend Data</li>
<li>Free DataView software included</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/">AEMC Powerpad III 8333</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Powerpad III 8333 Three Phase Power Quality Analyzer</h3>
<p>The AEMC Powerpad III 8333 Three Phase Power Quality Analyzer is an easy-to-use, compact and shock resistant three-phase power quality analyzer. It enables technicians and engineers to measure and carry out diagnostics and power quality work on single- or three-phase networks. Three current and four voltage input terminals are provided are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.</p>
<p>Model 8333 has memory available for storing trend data, alarms, transients, and snapshot data. Capable of storing up to 12 screen snapshots, up to 51 captured transients that contain four cycles for each active input, and 4,000 alarm events from up to 10 different parameters. Trend data can also be recorded for days, weeks or even months.</p>
<p><img decoding="async" class="alignright wp-image-5822 size-full" title="AEMC 8336 Power Quality Analyzer Kit" src="https://dataloggerinc.com/wp-content/uploads/2016/11/8336-kit.jpg" alt="AEMC 8336 Power Quality Analyzer Kit" width="200" height="120" /></p>
<p>Kit includes three MN193 current probes, four black 10 ft voltage leads, four black alligator clips, twelve color-coded input ID markers, NiMH battery, 110/240V power adapter with USB stick supplied with product user manual and DataView software.</p>
<p>Applications include:</p>
<ul>
<li>Verification of power distribution circuits</li>
<li>In-plant troubleshooting of power distribution panels and individual machinery</li>
<li>Monitor pad mount transformers and phase unbalances</li>
<li>Determine harmonic problems originating from source or load</li>
<li>Determine transformer K-Factor</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/">AEMC Powerpad III 8333</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC Powerpad III 8336</title>
		<link>https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 30 Nov 2016 21:47:39 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=5820</guid>

					<description><![CDATA[<ul>
<li>Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems</li>
<li>Measurement of TRMS currents up to 10,000Arms (sensor dependent)</li>
<li>Direct measurement of neutral current &#38; voltage</li>
<li>Frequency measurement (40 to 69Hz)</li>
<li>Record and display trend data as fast as once per second for one month for up to 41 variables</li>
<li>Transient detection on all V and I inputs (up to 210)</li>
<li>Measures harmonics for voltage, current or power up to the 50th harmonic</li>
<li>Recording, time stamping and characterization of disturbance</li>
<li>2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory</li>
<li>65µs/sample trend recording</li>
<li>Includes free DataView® software for configuring data storage, real-time display, analysis and report generation</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/">AEMC Powerpad III 8336</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignright wp-image-5822 size-full" title="AEMC 8336 Power Quality Analyzer Kit" src="https://dataloggerinc.com/wp-content/uploads/2016/11/8336-kit.jpg" alt="AEMC 8336 Power Quality Analyzer Kit" width="200" height="120" />The Powerpad III 8336 Three Phase Power Quality Analyzer from AEMC is an easy-to-use, compact and shock resistant data logger kit. Technicians and engineers can measure and carry out diagnostics and power quality work on one-, two- or three-phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV and 1000V CAT III.</p>
<p>The Powerpad III 8336 Three Phase Power Quality Analyzer has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. Capable of storing up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input or inrush data for up to 10 minutes, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.</p>
<p>Kit includes:</p>
<ul>
<li>5 black 10 ft voltage leads</li>
<li>5 black alligator clips</li>
<li>12 color-coded input ID markers</li>
<li>USB cable</li>
<li>NiMH battery</li>
<li>110/240V power adapter with US power cord</li>
<li>Toolbag</li>
<li>Soft carry pouch</li>
<li>User guide</li>
<li>USB stick supplied with product manual and DataView® software</li>
</ul>
<p>Applications include:</p>
<ul>
<li>Verification of power distribution circuits</li>
<li>In-plant troubleshooting of power distribution panels and individual machinery</li>
<li>Monitor pad mount transformers and phase unbalances</li>
<li>Determine harmonic problems originating from source or load</li>
<li>Determine transformer Factor-K</li>
<li>Energy metering (kVAh, VARh, kWh)</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/">AEMC Powerpad III 8336</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder PV-3</title>
		<link>https://dataloggerinc.com/product/pv-3-solar-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/pv-3-solar-data-logger/</guid>

					<description><![CDATA[<ul>
<li>Records Solar Irradiance, 0-1500W/m-2</li>
<li>PV system output Vdc to 300V, Idc to 100A</li>
<li>Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other applications</li>
<li>Accurately record DC voltages up to 60Vdc</li>
<li>Two voltage input channels and one current channel</li>
<li>Records VAvg, VMax &#38; VMin on 2 channels. Data is stored in non-volatile memory</li>
<li>Kit includes logger, fused voltage input leads, DC current probe, pyranometer, USB lead, 12Vdc PSU, software and carry case</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pv-3-solar-data-logger/">Electrocorder PV-3</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>PV-3 Solar Data Logger</h3>
<p>The PV-3 solar data logger is used by installers, householders, renewable energy companies to check PV (photo voltaic) installations. It can record solar irradiation up to 1,500W/m2 (watts per square metre), DC Voltage and DC Current produced by the panel, allowing you to assess the performance of a solar energy installation.</p>
<p>Why is the Electrocorder solar data logger better than other similarly priced competitors? The Electrocorder range use a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz and 20ms at 50Hz. At the end of each averaging period, 3 quantities are saved for each channel, the TRMS average, the Max, which is the highest cycle value during the period and the Min, lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer.</p>
<p>When recording the Electrocorder will store the average voltage (and current if applied) over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) cycle values during that period.</p>
<p>The voltage levels are stored with dates and times. With the back-up battery, the Electrocorder can continue to record for 4 weeks. An external 12Vdc PSU input is available, to allow for prolonged logging without batteries. Memory capacity of 32,000 TRMS voltage values per channel (10 bit).</p>
<p>The post <a href="https://dataloggerinc.com/product/pv-3-solar-data-logger/">Electrocorder PV-3</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder DC-3VA</title>
		<link>https://dataloggerinc.com/product/dc-3va-dc-voltage-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:47 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/dc-3va-two-channel-dc-voltage-and-current-logger-kit/</guid>

					<description><![CDATA[<ul>
<li>2 Channels Voltage (300V), 1 Channel Current +/-10A or +/-100A</li>
<li>Records DC voltage and current</li>
<li>Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other application</li>
<li>Accurately record DC voltages and DC current</li>
<li>Records VAvg, VMax &#38; VMin on 2 channels, Iavg, Imax &#38; Imin on 1 channel</li>
<li>Kit includes Logger, Carry Case, Electrosoft software, three fused voltage leads, DC current probe, USB lead &#38; 12Vdc PSU</li>
<li>Memory capacity of 32,000 true RMS values per channel (10 bit), up to 300 days continuous recording</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dc-3va-dc-voltage-current-data-logger/">Electrocorder DC-3VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Electrocorder DC-3VA DC Voltage Current Data Logger</h3>
<p>The DC-3VA DC Voltage Current Data Logger is a two-channel data logger specifically designed to accurately monitor one or two DC voltage channels, 1V to 300Vdc, and one DC current channel, allowing you to monitor PV (photovoltaic) cell output, DC charger performance, as well as many other applications &#8211; like DC motors. The stored data is uploaded to a PC via the supplied USB cable.</p>
<p>The kit includes a data logger, fused voltage leads, DC current probes, USB lead, 12Vdc PSU, Electrosoft software, and a carry case. IP65-rated enclosure.</p>
<p>When recording, the Electrocorder will store the average DC voltage and DC current over the period chosen (1 sec to 60 min), it will also record the highest (max) &amp; lowest (min) values during that period.</p>
<p>The advantage of Electrocorder products over most others is that our Data Loggers constantly sample information (recording the Minimum, Maximum, and Average reading) over the set period. Many other products only take ‘snapshots’ of what is going on and can miss 99.9% of the data that is critical to your analysis.</p>