<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Featured Industrial Application Products - CAS Dataloggers</title>
	<atom:link href="https://dataloggerinc.com/products/featured-industrial-application-products/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/featured-industrial-application-products/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Mon, 28 Jul 2025 18:20:09 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Featured Industrial Application Products - CAS Dataloggers</title>
	<link>https://dataloggerinc.com/products/featured-industrial-application-products/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>VersaLog VL-DCVC</title>
		<link>https://dataloggerinc.com/product/versalog-vl-dcvc/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Mon, 21 Apr 2025 13:53:59 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995460</guid>

					<description><![CDATA[<ul>
<li>16-bit analog-to-digital converter</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>Seven range programmable voltage and current external input channels</li>
<li>Can be accessed via USB, MODEM, or Ethernet connections</li>
<li>10-year battery life</li>
<li>Fast sampling mode</li>
<li>Alarm and excitation output</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/versalog-vl-dcvc/">VersaLog VL-DCVC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The VersaLog VL-DCVC Voltage Current Temperature Data Logger</h3>
<p>The VL-DCVC Voltage Current Data Logger is an 8-channel, battery-powered, stand-alone voltage, current, and temperature data logger. It records up to 8 megabytes of data and stores it in non-volatile flash memory for later retrieval. Input voltage/current signals can be from sensors, transducers, transmitters or any other common voltage/current sources. Its on-board temperature channel provides environment monitoring and temperature compensation.</p>
<p>Featuring an aluminum enclosure and conformal coating PCB, the logger has excellent performance in the harshest industrial environment. Powered by a 16-bit ADC and programmable input range, the logger is well suited to science and laboratory applications where precise and accurate measurement is critical. Simplify communications and engineering unit conversion with the Plug &amp; Play USB port and versatile custom equations. Simply plug the logger into a computer&#8217;s USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing, and more</p>
<p><strong>Siteview software required (1 license per site) and sold separately</strong></p>
<h2>Memory Capacity</h2>
<hr />
<p>All VersaLog data loggers come with 8MB onboard flash memory. The following table shows the relationship between the number of enabled channels, sampling interval and max time span of logging.</p>
<table border="1" width="66%">
<tbody>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Sampling Interval</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Number of Channels</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Logging Capacity</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3.98 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">727 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">181 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">242 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">121 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">30 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">24 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">12 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">58 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">29 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">7.2 hours</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://dataloggerinc.com/product/versalog-vl-dcvc/">VersaLog VL-DCVC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>dataTaker DT80W</title>
		<link>https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 29 Jun 2017 20:53:03 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=9097</guid>

					<description><![CDATA[<h2>5 Channel Universal Input Data Logger with WiFi</h2>
<ul>
<li>Up to 15 Analog (± 50V) sensor inputs</li>
<li>Expandable to 300 analog inputs</li>
<li>12 flexible digital terminals</li>
<li>2 Serial ‘Smart Sensor’ ports</li>
<li>SDI-12 (multiple networks)</li>
<li>Programmable Analog Output</li>
<li>Integrated WiFi</li>
<li>Automatic data transfer via email or FTP</li>
<li>Sending alarm via SMS or email</li>
<li>Modbus for SCADA connection</li>
<li>USB memory for easy data and program transfer</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/">dataTaker DT80W</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>DT80W Universal Input Data Logger with Integrated WiFi</h2>
<h3>Versatile Measurement</h3>
<p>The DT80W WiFi Universal Input Data Logger allows you to connect an array of sensors through versatile analog and digital channels, high-speed counter inputs, phase encoder inputs, and programmable serial sensor channels.</p>
<p>Temperature, voltage, current, 4-20mA loops, resistance, bridges, strain gauges, frequency, digital, serial, and calculated measurements can all be scaled, logged, and returned in engineering units or within statistical reporting.</p>
<p>Set up sampling, logging, alarm, and control tasks to suit your requirements while interfaces for smart sensors, GPS, and other intelligent devices expand the dataTaker DT80W flexibility.</p>
<h3>Local Wireless Access</h3>
<p>With wireless access, no need to have a physical connection to the logger. Send the program, view and download the data, or even modify your settings on a nearby PC or Tablet wirelessly either as a Master (Access Point mode) or Slave (Client).</p>
<h3>Automatic Data Delivery</h3>
<p>On Client mode, dataTaker can have access to a local router and if the router has internet access it can utilize the DT80W’s automatic data delivery features to schedule your data to be automatically emailed to your inbox every day, week, month, or other time interval.</p>
<p>More sophisticated systems can make use of the automatic data delivery features to send logged data to an FTP server.</p>
<p>The post <a href="https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/">dataTaker DT80W</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-WF-TH</title>
		<link>https://dataloggerinc.com/product/vl-wf-th-wifi-thermistor-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 25 May 2017 23:46:18 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=7906</guid>

					<description><![CDATA[<div class="woocommerce-product-details__short-description">
<ul>
<li>The 16-bit analog-to-digital converter meets most high-resolution requirements</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>Eight external thermistor/resistor inputs</li>
<li>Both USB and WiFi (requires external power) interfaces</li>
<li>Wide sampling interval selections (1 second to 12 hours)</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
</div>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-th-wifi-thermistor-data-logger/">VersaLog VL-WF-TH</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The VersaLog VL-WF-TH Wireless Thermistor Temperature Data Logger</h3>
<p>The VL-WF-TH WiFi Thermistor Data Logger is an 8-channel, battery-powered, standalone, and WIFI-enabled thermistor data logger. The logger measures eight external thermistors and saves data in 8 megabytes of memory.</p>
<p>Embedded WIFI module allows remote data monitoring and downloading.</p>
<p>16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical.</p>
<p>Its aluminum enclosure makes it excellent in the harshest industrial environment.</p>
<p>Simply power the logger in WIFI covered area and access it from your computer for configuration, downloading graph viewing, and more…</p>
<p><strong><a href="https://dataloggerinc.com/product/siteview-software/">SiteView software</a> required (1 license per site) and sold separately. </strong></p>
<h3>Memory Capacity</h3>
<hr />
<p>All VersaLog data loggers come with 8MB onboard flash memory. The following table shows the relationship between the number of enabled channels, sampling interval, and max time span of logging.</p>
<table border="1" width="66%">
<tbody>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Sampling Interval</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Number of Channels</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Logging Capacity</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">7.96 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3.98 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">362 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1.33 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">242 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">60 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">48 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">24 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">6 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">116 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">58 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">14.4 hours</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-th-wifi-thermistor-data-logger/">VersaLog VL-WF-TH</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-WF-V</title>
		<link>https://dataloggerinc.com/product/vl-wf-v-wifi-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 25 May 2017 23:45:53 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=7909</guid>

					<description><![CDATA[<div class="woocommerce-product-details__short-description">
<ul>
<li>16-bit analog-to-digital converter</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>Both USB and Wi-Fi (requires external power) interfaces</li>
<li>Programmable input ranges (-5 VDC to 20 VDC)</li>
<li>Over 10 years of battery Life</li>
<li>Wide sampling interval selections (1 second to 12 hours)</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
</div>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-v-wifi-voltage-data-logger/">VersaLog VL-WF-V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The VL-WF-V Wi-Fi Voltage Data Logger is an 8-channel, battery-powered, standalone and Wi-Fi-enabled voltage data logger. The logger<br />
records eight external voltage sources and saves data in 8 MB memory.</p>
<p>Its aluminum enclosure makes it excellent in the harshest industrial environment.</p>
<p>Embedded Wi-Fi module allows remote data monitoring and downloading.</p>
<p>16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical.</p>
<p>Simply power the logger in Wi-Fi covered area and access it from your computer for configuration, downloading, graph viewing and more…</p>
<p><strong><a href="https://dataloggerinc.com/product/siteview-software/">Siteview software</a> required and sold separately. One license per site, can be used on multiple loggers. </strong></p>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-v-wifi-voltage-data-logger/">VersaLog VL-WF-V</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-WF-TC</title>
		<link>https://dataloggerinc.com/product/vl-wf-tc-wifi-thermocouple-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 25 May 2017 18:30:05 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=7901</guid>

					<description><![CDATA[<ul>
<li>Thermocouple: Type E, N, J, K, T</li>
<li>16-bit analog to digital converter</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>Programmable input ranges</li>
<li>Both USB and WiFi (requires external power) interfaces</li>
<li>Wide sampling interval selection (1 second to 12 hours)</li>
<li>10-year battery life</li>
<li>Rugged physical housing</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-tc-wifi-thermocouple-data-logger/">VersaLog VL-WF-TC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The VL-WF-TC WiFi Thermocouple Data Logger is an 8-channel, battery powered, standalone and WIFI-enabled thermocouple data logger. The logger records eight thermocouple inputs and saves data in 8MB memory.</p>
<p>Its aluminum enclosure makes it excellent in the harshest industrial environment.</p>
<p>Embedded WIFI module allows remote data monitoring and downloading.</p>
<p>16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical.</p>
<p>Simply power the logger in WIFI covered area and access it from your computer for configuration, downloading, graph viewing and more…</p>
<p><strong><a href="https://dataloggerinc.com/product/siteview-software/">Siteview software</a> required and sold separately. One license per site, can be used on multiple loggers. </strong></p>
<p>The post <a href="https://dataloggerinc.com/product/vl-wf-tc-wifi-thermocouple-data-logger/">VersaLog VL-WF-TC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-BR</title>
		<link>https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 22:31:33 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=4634</guid>

					<description><![CDATA[<ul>
<li>The 16-bit analog-to-digital converter meets most high-resolution requirements</li>
<li>The 4 MB Memory stores up to 2 million measurements</li>
<li>2.5V excitation with compensation</li>
<li>± 8 mV input range</li>
<li>Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps</li>
<li>10-year battery life</li>
<li>Fast sampling mode</li>
<li>Alarm and excitation output</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/">VersaLog VL-BR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The VL-BR Strain Gauge Bridge Data Logger is a single channel, battery powered, stand-alone strain gauge bridge data logger. It supports one 4/6 wire Wheatstone bridge by providing voltage excitation, excitation voltage compensation, and low-level signal amplification. Data is stored in nonvolatile flash memory for later retrieval.</p>
<p>The VL-BR Strain Gauge Bridge Data Logger features a measurement input voltage range of -8 mV to +8 mV to accommodate most common bridges with a sensitivity of up to 3 mV/V.</p>
<p>Featuring an aluminum enclosure and PCB coating, the logger has excellent performance in the harshest industrial environment.</p>
<p>Powered by 16-bit ADC and programmable input range, the logger is well suited to science and laboratory applications where precise and accurate measurement is critical.</p>
<p><a href="/product/siteview-software/">Siteview software</a> is required and sold separately. One license per site, can be used on multiple loggers.</p>
<p>The post <a href="https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/">VersaLog VL-BR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Expert Logger 400</title>
		<link>https://dataloggerinc.com/product/expert-logger-400/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 11 Oct 2016 19:10:04 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/expert-logger-400/</guid>

					<description><![CDATA[<h2>16 Channel Data Logger</h2>
<ul>
<li>16 Universal analog inputs (mV mA, TC, RTD)</li>
<li>Sampling rate 1000 m/sec</li>
<li>24 Digital inputs / outputs</li>
<li>6 Analog outputs</li>
<li>32 Gb Internal Storage</li>
<li><strong>Software required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-400/">Delphin Expert Logger 400</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Expert Logger 400 Data Acquisition System</h2>
<p>The Expert Logger 400 is Delphin‘s new generation of data loggers. It combines the latest communication technology with advanced measurement technology and is based on FPGA technology to make it especially powerful. It can process up to 16 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.</p>
<h3>Operation Made Simple</h3>
<p>Sensors are connected via plug-in screw terminals and a chart clearly shows how channels are arranged. Users always have a good overview of the channels despite their high density. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to take measurements from a 4-wire RTD.</p>
<h3>Configuration &#8211; Fast and Easy</h3>
<p>The Expert Logger 400 is simple to configure from a PC. These settings remain stored within the Expert Logger even when disconnected from the power supply. The device settings can also be read out and stored on a PC and analyzed offline without the need for a connected Expert Logger. The offline configuration settings are then simply read into the device when connected. The software used for configuration is simple to operate to let users fully focus on their measurement tasks.</p>
<h3>Intelligent Signal Processing</h3>
<p>Signal processing using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo further computation and recording. Integrators directly calculate volumes or quantities from time-related measurement data such as mass and discharge flow rates. Limit values can monitor measurement data and be used to switch digital outputs or automatically send emails. Complex signal processing is possible using pulse counters, stop-clock functions, and operating-hours counter. Averages can be calculated and recorded as time-weighted or moving. The Expert Logger‘s software channels clearly set it apart from other loggers and make it very popular among users.</p>
<h3>Applications</h3>
<ul>
<li>Data logging</li>
<li>Environmental measurement technology</li>
<li>Product testing</li>
<li>Measurement data diagnosis</li>
<li>Lab data acquisition</li>
<li>Trials and tests</li>
<li>Energy optimization</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-400/">Delphin Expert Logger 400</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Expert Logger 300</title>
		<link>https://dataloggerinc.com/product/expert-logger-300/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 11 Oct 2016 19:06:43 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/expert-logger-300/</guid>

					<description><![CDATA[<h2>46 Channel Data Logger</h2>
<ul>
<li>46 Universal analog inputs (mV mA, TC, RTD)</li>
<li>Sampling rate 3000 m/sec</li>
<li>1 Digital Input</li>
<li>1 Digital Output</li>
<li>32 GB Internal Storage</li>
<li><strong>Software required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-300/">Delphin Expert Logger 300</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Expert Logger 300 Data Acquisition System</h2>
<p>The Expert Logger 300 is Delphin‘s new generation of data loggers. It combines the latest communication technology with advanced measurement technology, and is based on FPGA technology to make it especially powerful. It can process up to 46 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.</p>
<h3>Operation made simple</h3>
<p>Sensors are connected via plug-in screw terminals and a chart clearly shows how channels are arranged. Users always have a good overview of the channels despite their high density. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to take measurements from a 4-wire RTD.</p>
<h3>Configuration &#8211; Fast and Easy</h3>
<p>The Expert Logger 300 is simple to configure from a PC. These settings remain stored within the Expert Logger even when disconnected from the power supply. The device settings can also be read out and stored on a PC and analysed offline without the need for a connected Expert Logger. The offline configuration settings are then simply read into the device when connected. The software used for configuration is simple to operate to let users fully focus on their measurement tasks.</p>
<h3>Intelligent Signal Processing</h3>
<p>Signal processing using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo further computation and recording. Integrators directly calculate volumes or quantities from time related measurement data such as mass and discharge flow rates. Limit values can monitor measurement data and be used to switch digital outputs or automatically send emails. Complex signal processing is possible using pulse counters, stop-clock functions and operating-hours counter. Averages can be calculated and recorded as time-weighted or moving. The Expert Logger‘s software channels clearly set it apart from other loggers and make it very popular among users.</p>
<h3>Applications</h3>
<ul>
<li>Data logging</li>
<li>Environmental measurement technology</li>
<li>Product testing</li>
<li>Measurement data diagnosis</li>
<li>Lab data acquisition</li>
<li>Trials and tests</li>
<li>Energy optimization</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-300/">Delphin Expert Logger 300</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Expert Logger 200</title>
		<link>https://dataloggerinc.com/product/expert-logger-200/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 11 Oct 2016 19:02:32 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/expert-logger-200/</guid>

					<description><![CDATA[<h2>32 Channel Data Logger</h2>
<ul>
<li>32 Universal analog inputs (mV mA, TC, RTD)</li>
<li>Sampling rate 2000 m/sec</li>
<li>1 SDI-12 Sensor</li>
<li>4 Digital Inputs/Outputs</li>
<li>32 GB Internal Storage</li>
<li><strong>Software required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-200/">Delphin Expert Logger 200</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Expert Logger 200 Data Acquisition System</h2>
<p>The Expert Logger 200 is Delphin‘s new generation of data loggers. It combines the latest communication technology with advanced measurement technology, and is based on FPGA technology to make it especially powerful. It can process up to 32 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.</p>
<h3>Operation made simple</h3>
<p>Sensors are connected via plug-in screw terminals and a chart clearly shows how channels are arranged. Users always have a good overview of the channels despite their high density. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to take measurements from a 4-wire RTD.</p>
<h3>Configuration &#8211; Fast and Easy</h3>
<p>The Expert Logger is simple to configure from a PC. These settings remain stored within the Expert Logger even when disconnected from the power supply. The device settings can also be read out and stored on a PC and analysed offline without the need for a connected Expert Logger. The offline configuration settings are then simply read into the device when connected. The software used for configuration is simple to operate to let users fully focus on their measurement tasks.</p>
<h3>Intelligent Signal Processing</h3>
<p>Signal processing using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo further computation and recording. Integrators directly calculate volumes or quantities from time related measurement data such as mass and discharge flow rates. Limit values can monitor measurement data and be used to switch digital outputs or automatically send emails. Complex signal processing is possible using pulse counters, stop-clock functions and operating-hours counter. Averages can be calculated and recorded as time-weighted or moving. The Expert Logger‘s software channels clearly set it apart from other loggers and make it very popular among users.</p>
<h3>Applications</h3>
<ul>
<li>Data logging</li>
<li>Environmental measurement technology</li>
<li>Product testing</li>
<li>Measurement data diagnosis</li>
<li>Lab data acquisition</li>
<li>Trials and tests</li>
<li>Energy optimization</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-200/">Delphin Expert Logger 200</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-DCC-HR</title>
		<link>https://dataloggerinc.com/product/vl-dcc-hr-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:47 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/dcc-hr-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>The 16-bit analog-to-digital converter meets most high-resolution requirements</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>One onboard thermistor channel monitors ambient temperature</li>
<li>Seven 0-20mA external input channels cover wide measurement requirements</li>
<li>Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps</li>
<li>Fast sampling mode</li>
<li>Alarm and excitation output</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/vl-dcc-hr-current-data-logger/">VersaLog VL-DCC-HR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The VersaLog VL-DCC-HR Current Data Logger</h3>
<p>The VL-DCC-HR Current Data Logger is an 8-channel, battery-powered, stand-alone DC current data logger. It records up to 8 megabytes of data and stores it in non- volatile flash memory for later retrieval. Input current signals can be from sensors, transducers, transmitters or any other common current sources.</p>
<p>Featuring an aluminum enclosure, the VL-DCC-HR Current Data Logger has excellent performance in the harshest industrial environment.</p>
<p>Powered by a 16-bit ADC and programmable input range, the logger is well suited to science and laboratory applications where precise and accurate measurement is critical.</p>
<h3>Memory Capacity</h3>
<hr />
<p>All VersaLog data loggers come with 8MB onboard flash memory. The following table shows the relationship between the number of enabled channels, sampling interval and max time span of logging.</p>
<table border="1" width="66%">
<tbody>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Sampling Interval</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Number of Channels</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Logging Capacity</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3.98 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">727 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">181 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">242 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">121 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">30 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">24 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">12 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">58 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">29 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">7.2 hours</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://dataloggerinc.com/product/vl-dcc-hr-current-data-logger/">VersaLog VL-DCC-HR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
