<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas Monitoring - CAS Dataloggers</title>
	<atom:link href="https://dataloggerinc.com/products/gas-monitoring/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/gas-monitoring/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Tue, 14 Apr 2026 13:23:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Gas Monitoring - CAS Dataloggers</title>
	<link>https://dataloggerinc.com/products/gas-monitoring/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OdaLog G20N</title>
		<link>https://dataloggerinc.com/product/odalog-g20n/</link>
					<comments>https://dataloggerinc.com/product/odalog-g20n/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 14 Apr 2026 13:16:11 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=997472</guid>

					<description><![CDATA[<ul>
<li>ATEX, IECEx Certified</li>
<li>Long deployment period of up to 90 days</li>
<li>Smart sensor with predictive maintenance and health indication</li>
<li>An 8GB SD card allows 10 million data points</li>
<li>Accompanied by the OdaStat-Nx software</li>
<li>Specifically designed for harsh wastewater environments</li>
<li>USB, Bluetooth, MODBUS communication</li>
</ul>
<p><strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20n/">OdaLog G20N</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>OdaLog G20N &#8211; Simple and Effective Gas Monitoring<br />
Now with Smart Sensor technology</h3>
<p>The OdaLog® G20N is the next generation of the industry-leading OdaLog family, now with a digital smart sensor, enabling predictive maintenance and a long in-field deployment of up to 90 days. OdaLog G20N is rated to IP68, ATEX/IECEx certified, and with Bluetooth, USB, and Modbus built in, data access is easy &#8211; manually or via an integrated system.</p>
<h4>Typical Gas Monitoring Areas:</h4>
<ul>
<li>Sewer collection lines</li>
<li>Water treatment plants</li>
<li>Volcanoes</li>
<li>Manholes</li>
<li>Chemical Plants</li>
<li>Drain and pits</li>
<li>Storage and Warehouses</li>
</ul>
<p>You can learn more about the dangers of exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20n/">OdaLog G20N</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/odalog-g20n/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PR1000Ex</title>
		<link>https://dataloggerinc.com/product/pr1000ex/</link>
					<comments>https://dataloggerinc.com/product/pr1000ex/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 30 May 2025 19:31:16 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995879</guid>

					<description><![CDATA[<ul>
<li class="ai-optimize-35">Pressure Range: 0-5000 PSIA</li>
<li class="ai-optimize-36">Temperature Range: -40°C to +80°C</li>
<li class="ai-optimize-32">Rugged &#38; Reusable</li>
<li class="ai-optimize-33">Fully Submersible</li>
<li class="ai-optimize-37">CE compliant</li>
<li class="ai-optimize-42"><strong>This product is made to order and is not returnable or cancellable</strong></li>
<li class="ai-optimize-38"><strong>An IFC400 USB Docking Station is required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pr1000ex/">PR1000Ex</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>PR1000Ex Intrinsically Safe Pressure and Temperature Data Logger</h2>
<p>The PR1000Ex is an intrinsically safe pressure and temperature data logger used to accurately monitor and record at user programmable reading intervals. It carries hazardous location, intrinsically safe certification in accordance with the latest issue of IECEx 60079-0, IECEx 60079-11 and Directive 2014/34/EU (known as ATEX). The rugged stainless steel design allows for the device to be placed in harsh environments, which makes it well suited for use with air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems.</p>
<p>The PR1000Ex can also monitor and record transient pressure through software configuration of user defined trigger thresholds and time periods. The logger can be configured to record measurements at rates as fast as 128Hz or as slow as once every 24 hours. The non-volatile memory has a capacity of over 2 million readings.</p>
<p>The PR1000Ex uses a stainless steel pressure strain gauge to accurately measure the pressure. The 1/4 inch NPT pressure port featured on the device allows for compatibility with a variety of fittings and adapters. The internal temperature sensor provides ambient temperature measurements. The PR1000Ex is also fully submersible. There are many different pressure ranges available to fit most any application.</p>
<h3>Features</h3>
<ul>
<li>Rugged</li>
<li>Reusable</li>
<li>Submersible</li>
<li>Programmable start time</li>
<li>Real-time operation</li>
<li>User-friendly</li>
<li>Low cost</li>
<li>CE compliant</li>
</ul>
<h3>Certified Intrinsically Safe</h3>
<ul>
<li>Electrical Protection Concepts: IEC: 60079-11 Ex ia – Ex ic, Intrinsic Safety Zones 0-2</li>
<li>Equipment Protection Level: Ga – Gc, Zones 0-2</li>
<li>Gas Groups: IIC P Statistics Export to Excel Tabular Data View</li>
<li>Temperature Class: T4</li>
</ul>
<h3>PR1000Ex Applications</h3>
<ul>
<li>Pneumatics</li>
<li>Process control systems</li>
<li>Gas compressors</li>
<li>Natural gas production</li>
<li>Lubrication systems</li>
<li>Chemical processing</li>
<li>Pulp and paper processing</li>
<li>Medical instrumentation</li>
<li>Environmental studies</li>
<li>Waste water treatment</li>
<li>HVAC</li>
<li>Oil &amp; gas industries</li>
<li>EtO Sterilization</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pr1000ex/">PR1000Ex</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/pr1000ex/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PR1000IS</title>
		<link>https://dataloggerinc.com/product/pr1000is/</link>
					<comments>https://dataloggerinc.com/product/pr1000is/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 30 May 2025 19:31:16 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995880</guid>

					<description><![CDATA[<ul>
<li class="ai-optimize-35">Pressure Range: 0-5000 PSIA</li>
<li class="ai-optimize-36">Temperature Range: -40°C to +80°C</li>
<li class="ai-optimize-32">Rugged &#38; Reusable</li>
<li class="ai-optimize-33">Fully Submersible</li>
<li class="ai-optimize-37">CE compliant</li>
<li class="ai-optimize-42"><strong>This product is made to order and is not returnable or cancellable</strong></li>
<li class="ai-optimize-38"><strong>An IFC400 USB Docking Station is required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pr1000is/">PR1000IS</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>PR1000IS Intrinsically Safe Pressure and Temperature Data Logger</h2>
<p>The PR1000IS is an intrinsically safe pressure and temperature data logger used to accurately monitor and record at user programmable reading intervals. It carries hazardous location, intrinsically safe certification in accordance with the latest issue of FM3600, FM3610. The rugged stainless steel design allows for the device to be placed in harsh environments, which makes it well suited for use with air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems.</p>
<p>The PR1000IS can also monitor and record transient pressure through software configuration of user defined trigger thresholds and time periods. The logger can be configured to record measurements at rates as fast as 128Hz or as slow as once every 24 hours. The non-volatile memory has a capacity of over 2 million readings.</p>
<p>The PR1000IS uses a stainless steel pressure strain gauge to accurately measure the pressure. The 1/4 inch NPT pressure port featured on the device allows for compatibility with a variety of fittings and adapters. The internal temperature sensor provides ambient temperature measurements. The PR1000IS is also fully submersible. There are many different pressure ranges available to fit most any application.</p>
<h3>Features</h3>
<ul>
<li>Rugged</li>
<li>Reusable</li>
<li>Submersible</li>
<li>Programmable start time</li>
<li>Real-time operation</li>
<li>User-friendly</li>
<li>Low cost</li>
<li>CE compliant</li>
</ul>
<h3>Certified Intrinsically Safe</h3>
<ul>
<li>Class I, II, III, Division 1, Groups A-G,-40 °C &lt; Tamb &lt; +80 °C, T4A</li>
<li>Class I, II, III, Division 2, Groups A-D, F, G, -40 °C &lt; Tamb &lt; +80 °C, T4A</li>
<li>Temperature Class: T4A</li>
<li>CAN/CSA-C22.2 No. 60079-0:15 P Statistics Export to Excel Tabular Data View</li>
<li>CAN/CSA-C22.2 No. 60079-11:14</li>
</ul>
<h3>PR1000IS Applications</h3>
<ul>
<li>Pneumatics</li>
<li>Process control systems</li>
<li>Gas compressors</li>
<li>Natural gas production</li>
<li>Lubrication systems</li>
<li>Chemical processing</li>
<li>Pulp and paper processing</li>
<li>Medical instrumentation</li>
<li>Environmental studies</li>
<li>Waste water treatment</li>
<li>HVAC</li>
<li>Oil &amp; gas industries</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/pr1000is/">PR1000IS</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/pr1000is/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog G20</title>
		<link>https://dataloggerinc.com/product/odalog-g20/</link>
					<comments>https://dataloggerinc.com/product/odalog-g20/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 01 Nov 2022 20:06:21 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com//?post_type=product&#038;p=985910</guid>

					<description><![CDATA[<ul>
<li>ATEX, IECEx Certified</li>
<li>Long deployment period of up to 90 days</li>
<li>Smart sensor with predictive maintenance and health indication</li>
<li>8GB SD card allows 10 million data points</li>
<li>Accompanied by OdaStat-Nx software</li>
<li>Specifically designed for harsh wastewater environments</li>
<li>USB, Bluetooth, MODBUS communication</li>
</ul>
<p><strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20/">OdaLog G20</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>OdaLog G20 &#8211; Simple and Effective Gas Monitoring<br />
Now with Smart Sensor technology</h3>
<p>The OdaLog® G20 is the next generation of the industry-leading OdaLog family, now with a digital smart sensor, enabling predictive maintenance and a long in-field deployment of up to 90 days. OdaLog G20 is rated to IP68, ATEX/IECEx certified, and with Bluetooth, USB, and Modbus built in, data access is easy &#8211; manually or via an integrated system.</p>
<h4>Typical Gas Monitoring Areas:</h4>
<ul>
<li>Sewer collection lines</li>
<li>Water treatment plants</li>
<li>Volcanoes</li>
<li>Manholes</li>
<li>Chemical Plants</li>
<li>Drain and pits</li>
<li>Storage and Warehouses</li>
</ul>
<p>You can learn more about the dangers of exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20/">OdaLog G20</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/odalog-g20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog RTx Wireless H2S Gas Logger</title>
		<link>https://dataloggerinc.com/product/rtx-h2s-logger/</link>
					<comments>https://dataloggerinc.com/product/rtx-h2s-logger/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 25 Feb 2020 16:52:48 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33910</guid>

					<description><![CDATA[<ul>
<li>Wireless transmission of H2S data using cellular technology</li>
<li>Designed for harsh wastewater environments with proven, robust double o-ring design</li>
<li>OdaStat-G software provides global access to H2S data and remote configuration changes</li>
<li>Up to 12-month battery life</li>
<li>Internal memory for up to 42,000 data points</li>
<li>Easy to read  large alphanumeric display</li>
<li>IrDA or BlueTooth communication link for local setup and download</li>
<li>Note: Data SIM Card is required</li>
<li><strong>Other gas types and ranges possible. Call us for more information</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/rtx-h2s-logger/">OdaLog RTx Wireless H2S Gas Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog RTx Wireless H2S Gas Logger is the next generation of OdaLog gas logger that utilizes a built-in GSM modem to transmit real-time gas concentration data to a dedicated Internet server that is remotely accessible using the latest OdaStat-G software application. The OdaLog RTx provides an M2M solution for the integration of device and sensor data with the big data, analytics, and other enterprise applications behind the IoT.</p>
<h3>RTx Wireless H2S Gas Logger Features:</h3>
<ul>
<li>Instrument Temp Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Temp Range: -10°C to +40°C (14°F to 104°F)</li>
<li>Ingress Protection: IP66/68</li>
<li>External Dimensions: 3&#8243; Diameter x 10.24&#8243; Tall [without antenna]</li>
<li>Weight:  34.5oz [with default battery type fitted]</li>
<li>Power Supply: 2 Replaceable D-Size 3.6 V Lithium Batteries</li>
<li>Battery Life/Run Time: Greater than 12 months (*depending on the signal strength and server transmission interval)</li>
<li>Data Logging Capacity: Up to 42,000 readings in total (local memory, unlimited server memory)</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
<li>Communication Module: Internal Quad-band modem (850-900/1800/1900MHz)</li>
<li>Tri-Band Waterproof Antenna: 7.5&#8243; High</li>
</ul>
<p>Three different detection ranges are available:</p>
<p>0-50 PPM</p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Chemical vendors<br />
• Wastewater treatment plants<br />
• Odor control consultants<br />
• Municipalities</p>
<p>We also have two standard OdaLog H2S loggers with a <a href="https://dataloggerinc.com/product/l2-h2s-sl/" target="_blank" rel="noopener noreferrer">Standard Sensor</a> and <a href="https://dataloggerinc.com/product/l2-h2s-ll/" target="_blank" rel="noopener noreferrer">Long-Term Sensor</a> plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind the exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/rtx-h2s-logger/">OdaLog RTx Wireless H2S Gas Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/rtx-h2s-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog L2 H2S Gas Logger &#8211; LL</title>
		<link>https://dataloggerinc.com/product/l2-h2s-ll/</link>
					<comments>https://dataloggerinc.com/product/l2-h2s-ll/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 25 Feb 2020 14:22:09 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33860</guid>

					<description><![CDATA[<p>• Designed for harsh wastewater environments with proven, robust double o-ring design<br />
• Up to 12-month battery life<br />
• Extended sensor life for long term deployments<br />
• Internal memory for up to 42,000 data points<br />
• Easy to read large alphanumeric display<br />
• Fast downloading with IrDA, FiberOptic or BlueTooth Wireless communications link<br />
• Certified intrinsically safe to use in most hazardous environments<br />
• <strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-ll/">OdaLog L2 H2S Gas Logger &#8211; LL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog L2 H2S Gas Logger &#8211; LL has been specifically designed to withstand harsh environments typically found in the Wastewater Industry. The OdaLog is primarily used by locating it at or close to the source of Hydrogen Sulfide emissions such as within sewerage pumping stations and receiving manholes. Its purpose is to monitor and record H<sub>2</sub>S gas levels in sewage systems and treatment plants for later review and evaluation using OdaStat-G software.</p>
<h3>OdaLog L2 H2S Gas Logger &#8211; LL Features:</h3>
<ul>
<li>Instrument Operating Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Operating Range: -10°C to +40°C (14°F to 104°F)</li>
<li>IP66/68 Ingress Protection</li>
<li>Dimensions: 2.44” Diameter x 7.72” Tall</li>
<li>Weight: 14.8 oz</li>
<li>Power Supply: Replaceable C-Size Lithium Battery</li>
<li>Battery Life/Run Time: Greater than 8 months</li>
<li>Data Logging Capacity: Up to 42,000 readings</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
</ul>
<p><strong>Two different detection ranges are available:</strong></p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Gas monitoring in manholes, drains, and pits<br />
• Odor monitoring in sewer and streaming water<br />
• Ventilation pipes and rising mains<br />
• Inside sewer collection lines<br />
• Selected areas in treatment plants<br />
• Asset management and odor control</p>
<p>The L2 H2S Gas Logger &#8211; LL is also available with a <a href="https://dataloggerinc.com/product/l2-h2s-sl/" target="_blank" rel="noopener noreferrer">Standard sensor</a>, suitable for short-term deployment plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-ll/">OdaLog L2 H2S Gas Logger &#8211; LL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/l2-h2s-ll/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog L2 H2S Data Logger &#8211; SL</title>
		<link>https://dataloggerinc.com/product/l2-h2s-sl/</link>
					<comments>https://dataloggerinc.com/product/l2-h2s-sl/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 20 Feb 2020 16:50:10 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33841</guid>

					<description><![CDATA[<p>• Designed for harsh wastewater environments with proven, robust double o-ring design<br />
• Up to 12-month battery life<br />
• Internal memory for up to 42,000 data points<br />
• Easy to read large alphanumeric display<br />
• Fast downloading with IrDA or BlueTooth Wireless communications link<br />
• Certified intrinsically safe to use in most hazardous environments<br />
• <strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-sl/">OdaLog L2 H2S Data Logger &#8211; SL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog L2 H2S Data Logger has been specifically designed to withstand harsh environments typically found in the Wastewater Industry. The OdaLog is primarily used by locating it at or close to the source of Hydrogen Sulfide emissions such as within sewerage pumping stations and receiving manholes. Its purpose is to monitor gas levels to help control H<sub>2</sub>S gas in sewerage systems and treatment plants for later review and evaluation using OdaStat-G software.</p>
<h3>OdaLog L2 H2S Data Logger Features:</h3>
<ul>
<li>Instrument Operating Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Operating Range: -10°C to +40°C (14°F to 104°F)</li>
<li>IP66/68 Ingress Protection</li>
<li>Dimensions: 2.44” Diameter x 7.72” Tall</li>
<li>Weight: 14.8 oz</li>
<li>Power Supply: Replaceable C-Size Lithium Battery</li>
<li>Battery Life/Run Time: Greater than 8 months</li>
<li>Data Logging Capacity: Up to 42,000 readings</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
</ul>
<p>Four different detection ranges are available:</p>
<p>0-50 PPM</p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<p>0-2000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Gas monitoring in manholes, drains, and pits<br />
• Odor monitoring in sewer and streaming water<br />
• Ventilation pipes and rising mains<br />
• Inside sewer collection lines<br />
• Selected areas in treatment plants<br />
• Asset management and odor control</p>
<p>The L2 H2S Data Logger is also available with a <a href="https://dataloggerinc.com/product/l2-h2s-ll/" target="_blank" rel="noopener noreferrer">Long Term sensor</a>, which allows for longer deployment times (up to thirty days at a time) plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-sl/">OdaLog L2 H2S Data Logger &#8211; SL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/l2-h2s-sl/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
