<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Infinite Autonomous RTU &amp; Data Loggers from CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/infinite/rtu-data-loggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/infinite/rtu-data-loggers/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Wed, 28 May 2025 14:21:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Infinite Autonomous RTU &amp; Data Loggers from CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/infinite/rtu-data-loggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Infinite iLOGPlus-LAN</title>
		<link>https://dataloggerinc.com/product/ilogplus-lan-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 17:55:27 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ilogplus-lan-4-channel-data-loggerrtu-with-ethernet-interface/</guid>

					<description><![CDATA[<ul>
<li>4 Analog inputs</li>
<li>4 Digital inputs</li>
<li>2 Relay outputs</li>
<li>Storage for 40,000 measurements</li>
<li>Ethernet interface</li>
<li>Keypad and display</li>
<li>Expandable</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ilogplus-lan-data-logger/">Infinite iLOGPlus-LAN</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>iLOGPlus-LAN Data Logger</h3>
<p>The Infinite iLOGPlus-LAN Data Logger is an internet-enabled device, especially suited for remote data acquisition, distributed telemetry, and remote control. The units act as master devices and send alerts and data files on their own via FTP, email, and SMS. All types carry a built-in TCP/IP web server with live web pages that can be accessed by any Internet browser application. They accept and serve TCP and SMS commands for interactive operation in a SCADA system. Analog inputs and digital I/O are expandable using I/O expansion modules, plugging into a serial I/O expansion bus.</p>
<p>The device carries a built-in Ethernet/LAN adapter and can be directly hooked onto a local network. It can connect via a gateway or a GSM network router to the Internet. SMS alerting is supported with an external GSM modem attached to the local serial port.</p>
<p>Applications include:</p>
<ul>
<li>Water Resources Management</li>
<li>Weather Conditions Monitoring</li>
<li>Gas Distribution</li>
<li>Environmental Monitoring</li>
<li>Quality &amp; Safety Assurance, HACCP</li>
</ul>
<h3>Advanced Features</h3>
<p>The following characteristics are common to the 2 device types distinguished by the physical communication medium:</p>
<ul>
<li>Dual ARM7 processor architecture.</li>
<li>4 high-resolution analog inputs (AI1-AI4). Analog inputs can be expanded to 16 using 3 GE-AI-4 modular expansion modules.</li>
<li>2 constant current sources for PT-100 transducer excitation.</li>
<li>4 digital inputs for state recording and alarming. Two of them have pulse counting capability of up to 3 KHz supporting sensors with pulse output (power meters, flow meters, etc.). Digital inputs can be expanded to 16 by means of 3 GE-DIO-42 modular expansion modules.</li>
<li>2 relay outputs that are user (for remote control) or event triggered. Digital outputs can be expanded to 8 using 3 GE-DIO-42 modular expansion modules.</li>
<li>External DIN rail adaptor with screw terminals for convenient wiring (SCT-04E).</li>
<li>Power fail-safe memory for up to 40,000 channel records.</li>
<li>Alarm recording and annunciation via email and SMS.</li>
<li>Scheduled data transmission via email file attachment and FTP.</li>
<li>TCP and SMS ASCII commands for parameter setting and remote control.</li>
<li>Internal web server publishing a two-page HTML site on the internet, allowing real-time monitoring of the measurements and operating states and limiting parameter changing.</li>
<li>Serial communication RS232 port supporting local communication and convenient parameter setting and firmware upgrading using a PC and the powerful iLOGPlus Transporter utility.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ilogplus-lan-data-logger/">Infinite iLOGPlus-LAN</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Infinite iLOGPlus-GSM</title>
		<link>https://dataloggerinc.com/product/ilogplus-gsm-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 17:55:27 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ilogplus-gsm-4-channel-data-loggerrtu-with-gsm-modem/</guid>

					<description><![CDATA[<ul>
<li>4 Analog inputs</li>
<li>4 Digital inputs</li>
<li>2 Relay outputs</li>
<li>Storage for 40,000 measurements</li>
<li>Built-in GSM/GPRS modem</li>
<li>Internal web server</li>
<li>Keypad and display</li>
<li>Expandable</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ilogplus-gsm-data-logger/">Infinite iLOGPlus-GSM</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>iLOGPlus-GSM Data Logger</h3>
<p>Infinite iLOGPlus-GSM Data Logger is internet enabled devices, especially suited for remote data acquisition, distributed telemetry, and remote control. The units act as master devices and send alerts and data files on their own via FTP, email, and SMS. All types carry a built-in TCP/IP webserver with live webpages that can be accessed by any Internet browser application. They accept and serve TCP and SMS commands for interactive operation in a SCADA system. Analog inputs and digital I/O are expandable by means of I/O expansion modules, plugging on a serial I/O expansion bus.</p>
<p>The device carries a built-in GSM/GPRS modem and can automatically connect via a mobile telephony network to an ISP provider, to transmit its data via email or FTP and alerts via email or SMS. The unit controls the internal modem power supply for power saving purposes in applications with battery operation.</p>
<p>Applications include:</p>
<ul>
<li>Water Resources Management</li>
<li>Weather Conditions Monitoring</li>
<li>Gas Distribution</li>
<li>Environmental Monitoring</li>
<li>Quality &amp; Safety Assurance, HACCP</li>
</ul>
<h3>Advanced Features</h3>
<p>The following characteristics are common to the 2 device types distinguished by the physical communication medium:</p>
<ul>
<li>Dual ARM7 processor architecture.</li>
<li>4 high resolution analog inputs (AI1-AI4). Analog inputs can be expanded to 16 by means of 3 GE-AI-4 modular expansion modules.</li>
<li>2 constant current sources for PT-100 transducer excitation.</li>
<li>4 digital inputs for state recording and alarming. Two of them have pulse counting capability up to 3 KHz supporting sensors with pulse output (power meters, flow meters, etc.). Digital inputs can be expanded to 16 by means of 3 GE-DIO-42 modular expansion modules.</li>
<li>2 relay outputs that are user (for remote control) or event triggered. Digital outputs can be expanded to 8 by means of 3 GE-DIO-42 modular expansion modules.</li>
<li>External DIN rail adaptor with screw terminals for convenient wiring (SCT-04E).</li>
<li>Power fail safe memory for up to 40,000 channel records.</li>
<li>Alarm recording and annunciation via email and SMS.</li>
<li>Scheduled data transmission via email file attachment and FTP.</li>
<li>TCP and SMS ASCII commands for parameter setting and remote control.</li>
<li>Internal web server publishing a two pages HTML site on the internet, allowing real time monitoring of the measurements and operating states and allowing limited parameter changing.</li>
<li>Serial communication RS232 port supporting local communication and convenient parameter setting and firmware upgrading using a PC and the powerful iLOGPlus Transporter utility.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ilogplus-gsm-data-logger/">Infinite iLOGPlus-GSM</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Infinite BSC-50E</title>
		<link>https://dataloggerinc.com/product/bsc-50e-remote-alarming-system/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 17:55:27 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/infinite-bsc-50e-remote-alarming-system/</guid>

					<description><![CDATA[<ul>
<li>4 Digital or 2 digital/2 analog inputs</li>
<li>Built-in GSM/GPRS modem</li>
<li>Up to 10 year battery life</li>
<li>External sensor excitation</li>
<li>SMS Messaging</li>
<li>Optional IP67 enclosure</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/bsc-50e-remote-alarming-system/">Infinite BSC-50E</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>BSC-50E Remote Alarming System</h3>
<p>The BSC-50E Remote Alarming System is an ultra low power, wireless RTU with data logging and alarming capabilities. The battery-powered RTU incorporates a quad-band GSM/GPRS modem, four digital inputs, two analog inputs, one pulse counter input and multiple excitation options for powering measuring transducers. A Lithium Thionyl battery provides autonomous operation for over 10 years.</p>
<p>Applications include:</p>
<ul>
<li>Water Resources Management</li>
<li>Weather Conditions Monitoring</li>
<li>Power Grid</li>
<li>Gas Distribution</li>
<li>Environmental Monitoring</li>
<li>Telecom &amp; IT</li>
<li>Tank Level Measurement</li>
</ul>
<h3>The Infinite Advantage</h3>
<p>BSC-50E utilizes a dual processor architecture in order to combine extreme low power consumption with advanced processing and communication capabilities. A system controller (ultra-low power MCU) performs the measurement, data logging and alarm condition detection in continuous operation. A powerful communication processor, switched on and off by the system controller, performs data processing and controls communications through the internal wireless MODEM. The result is up to 50% power saving compared to respective units of the competition while performing the same tasks.</p>
<h3>Modes of Operation</h3>
<p>Modes of operation include autonomous battery operation and 9 to 24V external power supply operation with an uninterruptible transition to battery operation during a power outage.</p>
<h3>Measurements &amp; Data Logging</h3>
<p>The digital inputs are scanned in a closed loop by the system controller for detecting an alarm condition. Analog input scaling and alarm limits are user definable. The analog inputs are sampled according to the user-defined sampling rate. Sampling rate and sampling duration affect the battery life according to the transducer power supply requirements. Firmware V:7.0 introduces a dual set of sampling, logging, and data transmission rates. The basic set can be superseded by an alternate set on an event. Digital input states, analog input, and counter values can be used as trigger sources for rate changes. Ultra-low power standby mode followed by frequent data recording and transmission can be selected to fit the application needs while maximizing the battery life.</p>
<h3>Transducer Excitation</h3>
<p>The unit provides multiple excitation options for measuring transducers.</p>
<h3>Alerting &amp; Messaging</h3>
<p>SMS announcements include alert messages and periodical status messages for verifying unit availability. The unit supports discrete alerting for several users. Message texts are user definable.</p>
<h3>Setup and Remote Configuration</h3>
<p>The unit can be programmed locally through the serial port or remotely via SMS by using simple ASCII configuration commands. The command set features commands for configuring input alarm parameters, scaling parameters and alarm limits, timing parameters and defining user groups. BSC-50E can be remotely reconfigured by sending configuration commands via SMS to the unit during the periodical status message processing.</p>
<p>The post <a href="https://dataloggerinc.com/product/bsc-50e-remote-alarming-system/">Infinite BSC-50E</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Infinite ADU-500</title>
		<link>https://dataloggerinc.com/product/adu-500-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 17:55:27 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/infinite-adu-500-autonomous-rtu-data-logger/</guid>

					<description><![CDATA[<ul>
<li>Operating Temperature: -40 to 65°C</li>
<li>Internal Li battery</li>
<li>2 analog inputs, 3 digital inputs and one pulse counter input</li>
<li>SDI-12 sensor data acquisition</li>
<li>Several excitation options for external sensors</li>
<li>Maintenance free operation for over 10 years</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/adu-500-data-logger/">Infinite ADU-500</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>ADU-500 Data Logger</h3>
<p>The ADU-500 Data Logger is an ultra low power, wireless RTU with data logging and alarming capabilities. The battery-powered RTU incorporates three digital inputs, two analog inputs, one pulse counter input and multiple excitation options for powering measuring transducers. The device supports the acquisition of up to 48 measurement channels, based on the popular SDI-12 communication protocol. ADU-500 uses an internal 3G cell modem to automatically send data and alerts. A D-size Lithium Thionyl battery can provide autonomous operation for over 10 years.</p>
<p>Applications include:</p>
<ul>
<li>Water Resources Management</li>
<li>Weather Conditions Monitoring</li>
<li>Environmental Monitoring</li>
</ul>
<h3>The Infinite Advantage</h3>
<p>ADU-500 utilizes a dual processor architecture in order to combine extreme low power consumption with advanced processing and communication capabilities. A system controller (ultra-low power MCU) performs the measurement, data logging, and alarm condition detection on a periodical basis. A powerful communication processor switched on and off by the system controller, performs data processing and controls communications through the internal wireless MODEM. The result is up to 50% power saving compared to respective units of the competition while performing the same tasks.</p>
<h3>Measurements &amp; Data Logging</h3>
<p>The digital inputs are scanned by the system controller for detecting an alarm condition. Analog input gain, scaling and alarm limits are user definable. The analog inputs and SDI-12 sensors are sampled according to the user-defined sampling rate. Sampling rate and sampling duration affect the battery life according to the transducer power supply requirements.</p>
<h3>SDI-12 Serial Bus</h3>
<p>SDI-12 is an asynchronous, ASCII, serial communications protocol that was developed for intelligent sensory instruments that typically monitor environmental data. The communication is achieved by digital communications. The addressing system allows data recorder to communicate with several microprocessor-based sensors over a single line. ADU-500 is compliant to the SDI-12 Standard Version 1.2 and supports extended commands for sensor configuration, in terminal mode. ADU-500 can collect data from several SDI-12 sensors for a total amount of 48 measurement channels.</p>
<h3>RS-485, MODBUS</h3>
<p>ADU-500 supports acquisition from sensors with an RS-485 interface, using the popular MODBUS ASCII protocol. Up to 10 measurement channels from several sensors are supported.</p>
<h3>Transducer Excitation</h3>
<p>The unit provides multiple excitation options for measuring transducers.</p>
<h3>Alerting &amp; Messaging</h3>
<p>SMS announcements include alert messages and periodical Status messages for verifying unit availability. The unit supports discrete alerting for several users. Message texts are user definable.</p>
<h3>Data Transmission</h3>
<p>The ADU-500 Data Logger supports periodical data transmission according to user-defined parameters. The unit can send data via SMS to predefined users or to an internet server via FTP.</p>
<h3>Setup and Remote Configuration</h3>
<p>The unit can be programmed locally through the serial port or remotely via SMS by using simple ASCII configuration commands. The command set features commands for configuring input alarm parameters, scaling parameters and alarm limits, timing parameters and defining user groups. ADU-500 can be remotely reconfigured by sending configuration commands to the unit during the periodical status message processing.</p>