<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Influx Rebel LT CAN Bus Loggers &amp; Accessories</title>
	<atom:link href="https://dataloggerinc.com/products/influx/rebel-lt/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/influx/rebel-lt/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Tue, 31 Mar 2026 17:10:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Influx Rebel LT CAN Bus Loggers &amp; Accessories</title>
	<link>https://dataloggerinc.com/products/influx/rebel-lt/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Influx K-Box</title>
		<link>https://dataloggerinc.com/product/influx-k-box/</link>
					<comments>https://dataloggerinc.com/product/influx-k-box/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 21 May 2025 21:38:07 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995797</guid>

					<description><![CDATA[<ul>
<li>Up to 8 K-type connections at up to 20 Hz sampling rate</li>
<li>Instrumentation data time synchronized with recorded vehicle network data via CAN</li>
<li>Combined Voltage, Thermocouple and P.W.M./Digital measurements</li>
<li>Stackable with all K-series instrumentation modules</li>
<li>Cold junction compensation for accurate thermocouple measurement</li>
<li>Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file</li>
<li><strong>An 8% Tariff Surcharge will be added to this item at checkout</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/influx-k-box/">Influx K-Box</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="bgLayers_comp-lnabhzgh" class="MW5IWV" data-hook="bgLayers" data-motion-part="BG_LAYER comp-lnabhzgh">
<h2 data-motion-part="BG_MEDIA comp-lnabhzgh">Influx K-Box Multi-DAQ Module</h2>
<div id="bgMedia_comp-lnabhzgh" class="VgO9Yg" data-motion-part="BG_MEDIA comp-lnabhzgh"><span style="font-size: inherit;">Designed for accurate sensor measurement, with captured data being transmitted on the CAN Bus. The </span><span style="font-size: inherit;">Multi-DAQ K-Box </span><span style="font-size: inherit;">is ideal for applications that require a quick set-up and collection of thermocouples, analog, digital and PWM inputs. </span></div>
<div data-motion-part="BG_MEDIA comp-lnabhzgh"></div>
</div>
<div class="" data-mesh-id="comp-lnabhzghinlineContent" data-testid="inline-content">
<div data-mesh-id="comp-lnabhzghinlineContent-gridContainer" data-testid="mesh-container-content">
<div id="comp-kd8pp5a92" class="HcOXKn c9GqVL QxJLC3 lq2cno YQcXTT comp-kd8pp5a92 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Stackable with all of our K-series instrumentation modules, the K-Box includes our unique power down and WakeOnCAN feature, enabling quick installation on long term unattended fleet test vehicles.</span></p>
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Accurate sensor measurement data is transmitted periodically on the CAN Bus enabling multiple K-Series modules to be connected together and data recorded via our CAN data loggers.</span></p>
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">The K-Box CAN Bus settings, calibration and sampling rates are all easily configurable and stored even when not powered.</span></p>
<h3 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Key Features:</span></h3>
<ul>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Up to 8 K-type connections at up to 20 Hz sampling rate</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Software switchable voltage input ranges from +/-80V to +/-10V</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">8 Analog inputs with variable input sampling rates (8 channels at 1k Hz, 4 channels at 5k Hz)</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">PWM: 3 inputs frequency measurements, counters or pulse measurements</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Outputs: 4 Relay outputs (Optional)</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Regulated +5V and +24V output power supply for external sensors</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Supplied with configuration software, Influx K-Cal for Windows® and configurable via a DBC file</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Instrumentation data time synchronized with recorded vehicle network data via CAN</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Galvanic isolation between modules (enclosure, power, CAN BUS, analog input module and thermocouple input      module)</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Measurement accuracy: +/- 1 degree C, Measurement resolution: 0.1 degree C</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Analog channel over-voltage protection +/- 150 Volt</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Stackable ABS enclosure</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Supports PT100/1000 sensors via K-PT addon</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Supports IEPE sensors via K-IEPE addon</span></li>
<li class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Supports analog and digital BNC sensors via K-Bob add-on</span></li>
</ul>
<h3>Advantages</h3>
<ul>
<li>Combined Voltage, Thermocouple and P.W.M./Digital measurements</li>
<li>Cold junction compensation for accurate thermocouple measurement</li>
<li>High input impedance on Analogue inputs</li>
<li>WakeOnCAN and power down deep sleep mode</li>
</ul>
</div>
</div>
</div>
<p>The post <a href="https://dataloggerinc.com/product/influx-k-box/">Influx K-Box</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/influx-k-box/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Influx Rebel LT</title>
		<link>https://dataloggerinc.com/product/rebel-lt-vehicle-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 17:55:44 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/rebel-vehicle-data-logger/</guid>

					<description><![CDATA[<ul>
<li>2x CAN buses</li>
<li>1x K-Line</li>
<li>4x Analog Inputs</li>
<li>SDHC card logging</li>
<li>ABS enclosure</li>
<li>Supports J1939 and OBD logging</li>
<li>Connects to Module Analyser for on-line CAN Analyser functionality</li>
<li><strong>An 8% Tariff Surcharge will be added to this item at checkout</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/rebel-lt-vehicle-data-logger/">Influx Rebel LT</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<section id="panel-0" class="content active">The Rebel LT Vehicle Data Logger is a cost-effective CAN bus, K-Line data logging solution, available with GPS and 3G GPRS. In addition, these data loggers have 4 high-speed analog input channels and 4 digital inputs as standard. The Rebel LT supports advanced functionality such as CAN monitoring, CCP, xCP and UDS data logging.</section>
<section></section>
<section class="content active"></section>
<section class="content active">Features:</p>
<ul>
<li>2x CAN buses</li>
<li>1x K-Line</li>
<li>4x analog inputs</li>
<li>4x digital Input/Output channels</li>
<li>SDHC card logging up to 128GB</li>
<li>ABS enclosure</li>
<li>Supports J1939 and OBD logging</li>
<li>Connects to Module Analyzer for on-line CAN Analyzer functionality</li>
<li>Can be stacked with the Influx K-Box for sensors and thermocouples</li>
</ul>
<p>Options:</p>
<ul>
<li>Internal 18 Hz u-blox GPS with a socket for external antenna</li>
<li>1kHz internal XYZ accelerometer +/-16G max</li>
<li>3G Modem</li>
<li>K-Box</li>
<li>Rebel Dash display</li>
</ul>
</section>
<p>The post <a href="https://dataloggerinc.com/product/rebel-lt-vehicle-data-logger/">Influx Rebel LT</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DiaLog Software</title>
		<link>https://dataloggerinc.com/product/dialog-software/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:44 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/dialog-software/</guid>

					<description><![CDATA[<ul>
<li>Construct complex data logging configurations using a simple graphical interface</li>
<li>Collect data using ISO 14229 and 15765 Diagnostic Protocols, CCP and directly from a CAN bus</li>
<li>Efficient database system allows simple administration of configurations and data</li>
<li>USB, GPRS connectivity to Rebel data logger</li>
<li>Reconfigure and retrieve data by direct and remote connections</li>
<li>Live connection allows real time review of data while recording</li>
<li>Complex triggers with up to 30 conditions and 30 actions</li>
<li><strong>An 8% Tariff Surcharge will be added to this item at checkout</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dialog-software/">DiaLog Software</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>DiaLog Software &#8211; Easy to Use Intuitive Configuration Editor</h3>
<p>DiaLog Software is the configuration tool for the Influx Rebel family of loggers, which includes data analysis capabilities to form an intuitive software package. You can design your data logger to set up, store, and export files for distribution. DiaLog also comes with DataVue, allowing for advanced visual data analysis with the use of sophisticated graphing tools. DiaLog also offers configuration via Bluetooth or USB and imported industry-standard ASAM A2L files, ODX and CAN dbc formats.</p>
<p>Our intuitive editor allows you to configure the data logger easily. It is simple to collect data on several CAN buses using different protocols simultaneously.</p>
<p><b>Functions at a glance</b></p>
<ul>
<li>Builds the logger configurations</li>
<li>Connect the Rebel loggers via USB</li>
<li>Reconfigure Rebel loggers ready for data logging</li>
<li>Monitor live data while logging</li>
<li>Upload and analyze data recording files</li>
<li>In field firmware upgrades</li>
</ul>
<h3>On-Board Diagnostics</h3>
<p>DiaLog has an integrated database that stores OBD data allowing you to configure the Rebel data logger to record powertrain data on almost any modern road vehicle.</p>
<p><b>ODB Data</b></p>
<ul>
<li>Supports ISO14229, ISO14230, ISO15765</li>
<li>J1939 including DM1 messages</li>
<li>OBD Diagnostic Fault Codes</li>
<li>Advanced UDS functions such as Fast Data Acquisitions</li>
</ul>
<h3>Compatible with Industry Standards</h3>
<p>Most industry-standard file formats are supported. Recorded data can be exported to several formats, including batch file merging.</p>
<p><b>Supported Data Description File Formats:</b></p>
<ul>
<li>ASAM A2L – direct memory read operations</li>
<li>Vector® CAN DBC and LIN LDF</li>
<li>ODX/MDX/GDX – diagnostic databases</li>
<li>Fibex format</li>
</ul>
<p>Supported data analysis file formats:</p>
<ul>
<li>MDF (*.DAT)</li>
<li>Matlab™ MAT, MATStruct</li>
<li>Ncode®</li>
<li>National Instruments® TDM format</li>
<li>CSV for data analysis with Excel</li>
</ul>
<h3>Data Analysis</h3>
<p>DiaLog includes DataVue a professional data analysis package which allows you to analyze your data quickly.</p>
<p><b>Some Analysis Features</b></p>
<ul>
<li>Twin X axis Cursors</li>
<li>User-defined templates</li>
<li>Post calculated channels</li>
<li>Edit notes</li>
<li>Zooming in/out points of interest</li>
<li>Show sample points</li>
<li>Histograms</li>
<li>XY plotting</li>
<li>Statistical data</li>
</ul>
<p>DiaLog includes a server batch processing tool that enables you to merge and convert several days of data recording files in a single process.</p>
<p>The post <a href="https://dataloggerinc.com/product/dialog-software/">DiaLog Software</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
