<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>OdaLog Odor &amp; Gas Monitors from CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/odalog/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/odalog/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Tue, 14 Apr 2026 13:23:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>OdaLog Odor &amp; Gas Monitors from CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/odalog/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OdaLog G20N</title>
		<link>https://dataloggerinc.com/product/odalog-g20n/</link>
					<comments>https://dataloggerinc.com/product/odalog-g20n/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 14 Apr 2026 13:16:11 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=997472</guid>

					<description><![CDATA[<ul>
<li>ATEX, IECEx Certified</li>
<li>Long deployment period of up to 90 days</li>
<li>Smart sensor with predictive maintenance and health indication</li>
<li>An 8GB SD card allows 10 million data points</li>
<li>Accompanied by the OdaStat-Nx software</li>
<li>Specifically designed for harsh wastewater environments</li>
<li>USB, Bluetooth, MODBUS communication</li>
</ul>
<p><strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20n/">OdaLog G20N</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>OdaLog G20N &#8211; Simple and Effective Gas Monitoring<br />
Now with Smart Sensor technology</h3>
<p>The OdaLog® G20N is the next generation of the industry-leading OdaLog family, now with a digital smart sensor, enabling predictive maintenance and a long in-field deployment of up to 90 days. OdaLog G20N is rated to IP68, ATEX/IECEx certified, and with Bluetooth, USB, and Modbus built in, data access is easy &#8211; manually or via an integrated system.</p>
<h4>Typical Gas Monitoring Areas:</h4>
<ul>
<li>Sewer collection lines</li>
<li>Water treatment plants</li>
<li>Volcanoes</li>
<li>Manholes</li>
<li>Chemical Plants</li>
<li>Drain and pits</li>
<li>Storage and Warehouses</li>
</ul>
<p>You can learn more about the dangers of exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20n/">OdaLog G20N</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/odalog-g20n/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog G20</title>
		<link>https://dataloggerinc.com/product/odalog-g20/</link>
					<comments>https://dataloggerinc.com/product/odalog-g20/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 01 Nov 2022 20:06:21 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com//?post_type=product&#038;p=985910</guid>

					<description><![CDATA[<ul>
<li>ATEX, IECEx Certified</li>
<li>Long deployment period of up to 90 days</li>
<li>Smart sensor with predictive maintenance and health indication</li>
<li>8GB SD card allows 10 million data points</li>
<li>Accompanied by OdaStat-Nx software</li>
<li>Specifically designed for harsh wastewater environments</li>
<li>USB, Bluetooth, MODBUS communication</li>
</ul>
<p><strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20/">OdaLog G20</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>OdaLog G20 &#8211; Simple and Effective Gas Monitoring<br />
Now with Smart Sensor technology</h3>
<p>The OdaLog® G20 is the next generation of the industry-leading OdaLog family, now with a digital smart sensor, enabling predictive maintenance and a long in-field deployment of up to 90 days. OdaLog G20 is rated to IP68, ATEX/IECEx certified, and with Bluetooth, USB, and Modbus built in, data access is easy &#8211; manually or via an integrated system.</p>
<h4>Typical Gas Monitoring Areas:</h4>
<ul>
<li>Sewer collection lines</li>
<li>Water treatment plants</li>
<li>Volcanoes</li>
<li>Manholes</li>
<li>Chemical Plants</li>
<li>Drain and pits</li>
<li>Storage and Warehouses</li>
</ul>
<p>You can learn more about the dangers of exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/odalog-g20/">OdaLog G20</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/odalog-g20/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog DryDock</title>
		<link>https://dataloggerinc.com/product/drydock/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Mon, 19 Oct 2020 15:22:08 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=235556</guid>

					<description><![CDATA[<p><strong>Sensor Conditioning Kit</strong></p>
<p>Contains:</p>
<ul>
<li>OdaLog DryDock - suits OdaLog Type L2 and RTX</li>
<li>Highly-absorbent reusable desiccant beads change color from Orange to Blue when saturated</li>
<li>Desiccant beads can be easily regenerated or replaced when necessary</li>
<li>Humidity indicator card indicates internal humidity levels between 10%-50%</li>
<li>Clear molded cover to protect when not in use</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/drydock/">OdaLog DryDock</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog DryDock Sensor Conditioning Kit reduces recovery time for the <a href="https://dataloggerinc.com/downloads/odalog/" target="_blank" rel="noopener noreferrer">OdaLog</a> L2  and RTx loggers by half. This minimizes downtime and allows users to re-deploy the OdaLog loggers back into service sooner. The dry dock has color-changing beads that will indicate when it has reached its moisture adsorption limit.  When necessary, the beads can be easily regenerated by baking them at 105-110°C.</p>
<p>View the Quick User Guide for the DryDock <a href="https://dataloggerinc.com/wp-content/uploads/2020/10/TF_DryDock_QuickUserGuide1.pdf" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/drydock/">OdaLog DryDock</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OdaLog OdaTrak 4-20mA Adapter</title>
		<link>https://dataloggerinc.com/product/odatrak/</link>
					<comments>https://dataloggerinc.com/product/odatrak/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Mon, 19 Oct 2020 15:22:06 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=235869</guid>

					<description><![CDATA[<ul>
<li>Unique adapter fully sealed, proven &#38; robust design</li>
<li>Standard M20 electrical thread, special machined housing for easy mounting of the OdaTrak fiber optic cable</li>
<li>Outputs a fault signal on the 4-20mA line alerting user to fault condition</li>
<li>Rugged fiber optic cable</li>
<li>provides real-time data available when connected to a PLC or SCADA system</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/odatrak/">OdaLog OdaTrak 4-20mA Adapter</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog OdaTrak 4 to 20 mA adapter is primarily designed as an interface between the OdaLog gas logger and industrial control systems for the purpose of continuous, real-time optimization of chemical dosing odor control systems and connection to telemetry and other systems.</p>
<h2>OdaTrak Key Features:</h2>
<ul>
<li><strong>Easy to transmit data</strong> incorporates a 4-20mA adapter to transmit gas data using a fiber optic cable</li>
<li><strong>Real-time data</strong> readily available when connected to a PLC or SCADA system</li>
<li><strong>Specifically designed for harsh wastewater environments</strong>: unique adapter fully sealed, proven &amp; robust design</li>
<li><strong>Quick &amp; easy installation</strong>: standard M20 electrical thread, special machined housing for easy mounting of the OdaTrak fiber optic cable</li>
<li><strong>Programmed fault detection</strong>: OdaTrak detects loss of data from the OdaLog, will output a fault signal on the 4-20mA line alerting the user to a fault condition</li>
<li><strong>Special fiber optic cable</strong>: safe to use in most commonly found hazardous environments.</li>
<li><strong>Two models of cables are available</strong>, both with stainless steel connectors;<br />
1. standard coating for the fiber optic cable<br />
2. extra protective sheath added over the cable for harsher wastewater environments.</li>
</ul>
<h2>How It Works:</h2>
<p>Data sent from the OdaLog L2 logger equipped with a fiber optic interface over a fiber optic cable which is then read by the OdaTrak adapter. It then provides a corresponding signal on a 4-20mA loop which is powered externally.</p>
<p>The system enables the OdaLog L2 to be interfaced with telemetry and control systems to provide the user with real-time gas data.</p>
<p>In normal operation, the OdaTrak System requires two long-term OdaLog loggers so that they can be rotated in service with each logger in service no longer than four weeks, while the other OdaLog logger is allowed to recover either in fresh air or via the dry-dock.</p>
<p>The OdaTrak System is not intrinsically safe.</p>
<h2>Typical OdaTrak Applications:</h2>
<ul>
<li>Water Authorities</li>
<li>Odor Control Companies</li>
<li>Chemical Vendors</li>
<li>Water Treatment Plant Municipalities</li>
<li>Existing OdaLog L2 Users</li>
</ul>
<p>View more OdaLog Accessories <a href="https://dataloggerinc.com/products/odalog/odalog-accessories" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/odatrak/">OdaLog OdaTrak 4-20mA Adapter</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/odatrak/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog RTx Wireless H2S Gas Logger</title>
		<link>https://dataloggerinc.com/product/rtx-h2s-logger/</link>
					<comments>https://dataloggerinc.com/product/rtx-h2s-logger/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 25 Feb 2020 16:52:48 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33910</guid>

					<description><![CDATA[<ul>
<li>Wireless transmission of H2S data using cellular technology</li>
<li>Designed for harsh wastewater environments with proven, robust double o-ring design</li>
<li>OdaStat-G software provides global access to H2S data and remote configuration changes</li>
<li>Up to 12-month battery life</li>
<li>Internal memory for up to 42,000 data points</li>
<li>Easy to read  large alphanumeric display</li>
<li>IrDA or BlueTooth communication link for local setup and download</li>
<li>Note: Data SIM Card is required</li>
<li><strong>Other gas types and ranges possible. Call us for more information</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/rtx-h2s-logger/">OdaLog RTx Wireless H2S Gas Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog RTx Wireless H2S Gas Logger is the next generation of OdaLog gas logger that utilizes a built-in GSM modem to transmit real-time gas concentration data to a dedicated Internet server that is remotely accessible using the latest OdaStat-G software application. The OdaLog RTx provides an M2M solution for the integration of device and sensor data with the big data, analytics, and other enterprise applications behind the IoT.</p>
<h3>RTx Wireless H2S Gas Logger Features:</h3>
<ul>
<li>Instrument Temp Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Temp Range: -10°C to +40°C (14°F to 104°F)</li>
<li>Ingress Protection: IP66/68</li>
<li>External Dimensions: 3&#8243; Diameter x 10.24&#8243; Tall [without antenna]</li>
<li>Weight:  34.5oz [with default battery type fitted]</li>
<li>Power Supply: 2 Replaceable D-Size 3.6 V Lithium Batteries</li>
<li>Battery Life/Run Time: Greater than 12 months (*depending on the signal strength and server transmission interval)</li>
<li>Data Logging Capacity: Up to 42,000 readings in total (local memory, unlimited server memory)</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
<li>Communication Module: Internal Quad-band modem (850-900/1800/1900MHz)</li>
<li>Tri-Band Waterproof Antenna: 7.5&#8243; High</li>
</ul>
<p>Three different detection ranges are available:</p>
<p>0-50 PPM</p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Chemical vendors<br />
• Wastewater treatment plants<br />
• Odor control consultants<br />
• Municipalities</p>
<p>We also have two standard OdaLog H2S loggers with a <a href="https://dataloggerinc.com/product/l2-h2s-sl/" target="_blank" rel="noopener noreferrer">Standard Sensor</a> and <a href="https://dataloggerinc.com/product/l2-h2s-ll/" target="_blank" rel="noopener noreferrer">Long-Term Sensor</a> plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind the exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/rtx-h2s-logger/">OdaLog RTx Wireless H2S Gas Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/rtx-h2s-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog L2 H2S Gas Logger &#8211; LL</title>
		<link>https://dataloggerinc.com/product/l2-h2s-ll/</link>
					<comments>https://dataloggerinc.com/product/l2-h2s-ll/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 25 Feb 2020 14:22:09 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33860</guid>

					<description><![CDATA[<p>• Designed for harsh wastewater environments with proven, robust double o-ring design<br />
• Up to 12-month battery life<br />
• Extended sensor life for long term deployments<br />
• Internal memory for up to 42,000 data points<br />
• Easy to read large alphanumeric display<br />
• Fast downloading with IrDA, FiberOptic or BlueTooth Wireless communications link<br />
• Certified intrinsically safe to use in most hazardous environments<br />
• <strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-ll/">OdaLog L2 H2S Gas Logger &#8211; LL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog L2 H2S Gas Logger &#8211; LL has been specifically designed to withstand harsh environments typically found in the Wastewater Industry. The OdaLog is primarily used by locating it at or close to the source of Hydrogen Sulfide emissions such as within sewerage pumping stations and receiving manholes. Its purpose is to monitor and record H<sub>2</sub>S gas levels in sewage systems and treatment plants for later review and evaluation using OdaStat-G software.</p>
<h3>OdaLog L2 H2S Gas Logger &#8211; LL Features:</h3>
<ul>
<li>Instrument Operating Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Operating Range: -10°C to +40°C (14°F to 104°F)</li>
<li>IP66/68 Ingress Protection</li>
<li>Dimensions: 2.44” Diameter x 7.72” Tall</li>
<li>Weight: 14.8 oz</li>
<li>Power Supply: Replaceable C-Size Lithium Battery</li>
<li>Battery Life/Run Time: Greater than 8 months</li>
<li>Data Logging Capacity: Up to 42,000 readings</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
</ul>
<p><strong>Two different detection ranges are available:</strong></p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Gas monitoring in manholes, drains, and pits<br />
• Odor monitoring in sewer and streaming water<br />
• Ventilation pipes and rising mains<br />
• Inside sewer collection lines<br />
• Selected areas in treatment plants<br />
• Asset management and odor control</p>
<p>The L2 H2S Gas Logger &#8211; LL is also available with a <a href="https://dataloggerinc.com/product/l2-h2s-sl/" target="_blank" rel="noopener noreferrer">Standard sensor</a>, suitable for short-term deployment plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-ll/">OdaLog L2 H2S Gas Logger &#8211; LL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/l2-h2s-ll/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>OdaLog L2 H2S Data Logger &#8211; SL</title>
		<link>https://dataloggerinc.com/product/l2-h2s-sl/</link>
					<comments>https://dataloggerinc.com/product/l2-h2s-sl/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 20 Feb 2020 16:50:10 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=33841</guid>

					<description><![CDATA[<p>• Designed for harsh wastewater environments with proven, robust double o-ring design<br />
• Up to 12-month battery life<br />
• Internal memory for up to 42,000 data points<br />
• Easy to read large alphanumeric display<br />
• Fast downloading with IrDA or BlueTooth Wireless communications link<br />
• Certified intrinsically safe to use in most hazardous environments<br />
• <strong>Other gas types and ranges possible. Call us for more information</strong></p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-sl/">OdaLog L2 H2S Data Logger &#8211; SL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The OdaLog L2 H2S Data Logger has been specifically designed to withstand harsh environments typically found in the Wastewater Industry. The OdaLog is primarily used by locating it at or close to the source of Hydrogen Sulfide emissions such as within sewerage pumping stations and receiving manholes. Its purpose is to monitor gas levels to help control H<sub>2</sub>S gas in sewerage systems and treatment plants for later review and evaluation using OdaStat-G software.</p>
<h3>OdaLog L2 H2S Data Logger Features:</h3>
<ul>
<li>Instrument Operating Range: -20°C (-4°F) to 50°C (122°F)</li>
<li>Sensor Operating Range: -10°C to +40°C (14°F to 104°F)</li>
<li>IP66/68 Ingress Protection</li>
<li>Dimensions: 2.44” Diameter x 7.72” Tall</li>
<li>Weight: 14.8 oz</li>
<li>Power Supply: Replaceable C-Size Lithium Battery</li>
<li>Battery Life/Run Time: Greater than 8 months</li>
<li>Data Logging Capacity: Up to 42,000 readings</li>
<li>Sample Interval: Selectable from 1 second to 1 hour</li>
</ul>
<p>Four different detection ranges are available:</p>
<p>0-50 PPM</p>
<p>0-200 PPM</p>
<p>0-1000 PPM</p>
<p>0-2000 PPM</p>
<h3>Typical Applications:</h3>
<p>• Gas monitoring in manholes, drains, and pits<br />
• Odor monitoring in sewer and streaming water<br />
• Ventilation pipes and rising mains<br />
• Inside sewer collection lines<br />
• Selected areas in treatment plants<br />
• Asset management and odor control</p>
<p>The L2 H2S Data Logger is also available with a <a href="https://dataloggerinc.com/product/l2-h2s-ll/" target="_blank" rel="noopener noreferrer">Long Term sensor</a>, which allows for longer deployment times (up to thirty days at a time) plus models for other gases including ammonia, chlorine, sulfur dioxide, NO, NO2, carbon monoxide, and hydrogen cyanide.</p>
<p>You can learn more about the dangers behind exposure to Hydrogen Sulfide gas <a href="https://www.osha.gov/SLTC/hydrogensulfide/hazards.html" target="_blank" rel="noopener noreferrer">here</a>.</p>
<p>The post <a href="https://dataloggerinc.com/product/l2-h2s-sl/">OdaLog L2 H2S Data Logger &#8211; SL</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/l2-h2s-sl/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>