<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Stand-Alone Data Loggers for Any Application – CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/stand-alone-data-loggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/stand-alone-data-loggers/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Tue, 31 Mar 2026 17:13:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Stand-Alone Data Loggers for Any Application – CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/stand-alone-data-loggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>VersaLog VL-DCVC</title>
		<link>https://dataloggerinc.com/product/versalog-vl-dcvc/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Mon, 21 Apr 2025 13:53:59 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995460</guid>

					<description><![CDATA[<ul>
<li>16-bit analog-to-digital converter</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>Seven range programmable voltage and current external input channels</li>
<li>Can be accessed via USB, MODEM, or Ethernet connections</li>
<li>10-year battery life</li>
<li>Fast sampling mode</li>
<li>Alarm and excitation output</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/versalog-vl-dcvc/">VersaLog VL-DCVC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The VersaLog VL-DCVC Voltage Current Temperature Data Logger</h3>
<p>The VL-DCVC Voltage Current Data Logger is an 8-channel, battery-powered, stand-alone voltage, current, and temperature data logger. It records up to 8 megabytes of data and stores it in non-volatile flash memory for later retrieval. Input voltage/current signals can be from sensors, transducers, transmitters or any other common voltage/current sources. Its on-board temperature channel provides environment monitoring and temperature compensation.</p>
<p>Featuring an aluminum enclosure and conformal coating PCB, the logger has excellent performance in the harshest industrial environment. Powered by a 16-bit ADC and programmable input range, the logger is well suited to science and laboratory applications where precise and accurate measurement is critical. Simplify communications and engineering unit conversion with the Plug &amp; Play USB port and versatile custom equations. Simply plug the logger into a computer&#8217;s USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing, and more</p>
<p><strong>Siteview software required (1 license per site) and sold separately</strong></p>
<h2>Memory Capacity</h2>
<hr />
<p>All VersaLog data loggers come with 8MB onboard flash memory. The following table shows the relationship between the number of enabled channels, sampling interval and max time span of logging.</p>
<table border="1" width="66%">
<tbody>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Sampling Interval</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Number of Channels</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Logging Capacity</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3.98 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">727 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">181 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">242 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">121 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">30 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">24 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">12 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">58 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">29 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">7.2 hours</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://dataloggerinc.com/product/versalog-vl-dcvc/">VersaLog VL-DCVC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Influx K-TC</title>
		<link>https://dataloggerinc.com/product/k-tc/</link>
					<comments>https://dataloggerinc.com/product/k-tc/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 15 Feb 2024 14:13:05 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=991687</guid>

					<description><![CDATA[<ul>
<li>Each K-TC unit has up to 8, 16, or 32 thermocouple connections at a 20Hz sampling rate</li>
<li>Supports K, J, and T-type thermocouples</li>
<li>Simple signal configuration using a DBC file</li>
<li>Supports logging of timestamped temperature data inside an integrated eMMC (8GB)</li>
<li>Supplied with K-CAL configuration software for Windows®</li>
<li>Stackable ABS enclosure</li>
<li><strong>An 8% Tariff Surcharge will be added to this item at checkout</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/k-tc/">Influx K-TC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">The Influx K-TC </span>unit is available with 8, 16, or 32 channels; these can be stacked, and daisy chained to meet your requirements. Capture data from an unlimited number of thermocouples with the K-TC. The K-TC has galvanic isolation across USB, CAN, Power, and TC boards to ensure the protection of your devices. Supporting thermocouples type (K, J, &amp; T)</p>
<h3 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Mode 1 &#8211; </span>Standalone Temperature Data Logging</h3>
<p>Say goodbye to the need for a PC! Store your thermocouple data directly within the device using the internal 8GB eMMC storage, recording many months of data. This standalone data logging mode ensures user-friendliness and efficiency, enabling extended logging periods without requiring human interaction.</p>
<p class="font_8 wixui-rich-text__text"><span class="inherit-font-size wixui-rich-text__text"><span class="wixGuard wixui-rich-text__text">​</span></span>This capability can be used simultaneously with Mode 2.</p>
<h3 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Mode 2 &#8211; </span>Temperature Data to CAN</h3>
<p>Connect and transfer your thermocouple data onto the CAN bus using Influx Technology’s Rebel or ReXgen series, or another CAN bus logger. Use a Rebel series, ReXgen series, or an existing CAN bus data logger, to integrate the K-TC devices. Extend your capabilities by connecting the CAN bus output to a <a href="https://dataloggerinc.com/product/rexgen-air-fleet-data-recorder/" target="_blank" rel="noopener"><span class="wixui-rich-text__text">ReXgen Air</span></a> and remotely collect your thermocouple data on an AWS S3 server.</p>
<h3 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Mode 3 &#8211; </span>USB to PC</h3>
<p>Witness your thermocouple data come to life on your PC screen. Use the integrated oscilloscope feature of K-CAL to visualize and interpret your measurements in real-time. This mode provides a dynamic and user-friendly way to capture, view, and export your data to third-party formats for in-depth analysis.</p>
<div id="comp-lnsy36rs2" class="KcpHeO tz5f0K comp-lnsy36rs2 wixui-rich-text" data-testid="richTextElement">
<h3 class="font_2 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Stackable Enclosure</span></span></h3>
</div>
<div id="comp-lnsy36rt3" class="KcpHeO tz5f0K comp-lnsy36rt3 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text">The K-TC is a flexible device that can be used with any other CAN logger. The K-TC enclosure is designed to be stacked with other Influx devices.</p>
<ul>
<li class="font_8 wixui-rich-text__text">Stackable with <a href="https://dataloggerinc.com/product/rebel-lt-vehicle-data-logger/" target="_blank" rel="noopener">Rebel LT</a>, other K-TCs, and K-Series devices</li>
<li class="font_8 wixui-rich-text__text">Create a modular custom rig for your project</li>
<li class="font_8 wixui-rich-text__text">Crafted to meet the demanding standards of engineers</li>
<li class="font_8 wixui-rich-text__text">Enables multiple thermocouples</li>
</ul>
</div>
<h3>Software</h3>
<h4 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">K-CAL </span></h4>
<p class="font_8 wixui-rich-text__text">This powerful software allows for the configuration of up to five K-TCs at once and supports CAN message transmission with an oscilloscope for live data viewing. It also includes a DBC file for easy integration.</p>
<h4 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">K-Log</span></h4>
<p class="font_8 wixui-rich-text__text">Enables the Temperature data to be logged directly to the K-TC’s internal 8GByte eMMC.</p>
<p>The post <a href="https://dataloggerinc.com/product/k-tc/">Influx K-TC</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/k-tc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Delphin LoggitoLab Logger</title>
		<link>https://dataloggerinc.com/product/delphin-loggitolab-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Mon, 20 Sep 2021 19:21:01 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=982186</guid>

					<description><![CDATA[<ul>
<li>Plug &#38; Play – Flexible and ready-to-use desktop device with universal analog inputs and combined digital inputs/outputs</li>
<li>Optional laboratory and/or miniature thermal sockets to easily connect any current/voltage and temperature signals</li>
<li>Maximum measuring precision and resolution</li>
<li>Integrated server capability to instantly visualize and analyze measurement data via smartphone or tablet.</li>
<li>Versatile interfaces: LAN, USB, WLAN, OPC UA, Modbus TCP</li>
<li>Easy extendibility and scalability when extra channels needed</li>
<li>Optional internal data memory</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/delphin-loggitolab-logger/">Delphin LoggitoLab Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="">Accessing measurement data on the go</h2>
<p>LoggitoLab Logger is the device of choice when users require PC-independent operation with fail-safe internal data storage and smart analysis functions. The LoggitoLab Logger also features an optional server capability allowing measurement data to be instantly visualized and analyzed on smartphones or tablets. The optional WLAN interface allows full independence from existing network infrastructures.</p>
<header>
<h4 class="">Connection variants for your application</h4>
</header>
<div class="ce-textpic ce-left ce-below">
<div class="ce-bodytext">
<p>LoggitoLab provides the ideal solution for any application, whether for laboratory sockets for connecting voltage, current, resistance signal, or for miniature thermal sockets for instant connection of any thermocouples, or for a combination of both. All connection variants have eight analog inputs and two software-switchable digital inputs/outputs. A special feature is that the connection variants are available for both the LoggitoLab Logger and for the <a href="https://dataloggerinc.com/product/delphin-loggitolab-usb-logger/" target="_blank" rel="noopener">LoggitoLab USB</a>. You and your application, therefore, benefit from maximum flexibility.</p>
<p><strong>Connection variant: 8 AI-RTD</strong> with eight universal analog inputs to connect any voltage, current, and RTD signals in 2-, 3- and 4-wire technology via 4 mm lab sockets.</p>
<p><img decoding="async" class="size-full wp-image-982222 alignleft" src="https://dataloggerinc.com/wp-content/uploads/2021/09/labusb-2.png" alt="" width="300" height="128" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Connection variant: 8 TC</strong> with eight analog inputs for direct connection and high-precision measurement of any thermocouples via miniature thermal sockets.</p>
<p><img decoding="async" class="size-full wp-image-982220 alignleft" src="https://dataloggerinc.com/wp-content/uploads/2021/09/labusb-3.png" alt="" width="300" height="126" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Connection variant: 4 AI-RTD 4 TC</strong> for full flexibility with a combination of 4 analog inputs with 4 mm laboratory sockets and 4 analog inputs with miniature thermal sockets.</p>
<p><img decoding="async" class="size-full wp-image-982221 alignleft" src="https://dataloggerinc.com/wp-content/uploads/2021/09/labusb-1.png" alt="" width="300" height="131" /></p>
</div>
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://dataloggerinc.com/product/delphin-loggitolab-logger/">Delphin LoggitoLab Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-RTD-1</title>
		<link>https://dataloggerinc.com/product/vl-rtd-1-rtd-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 18 Apr 2018 15:44:43 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=17324</guid>

					<description><![CDATA[<ul>
<li>16-bit Analog-to-Digital Converter</li>
<li>8-megabyte memory stores up to 4 million measurements</li>
<li>1 On-Board Thermistor Channel</li>
<li>4 RTD Input Channels</li>
<li>USB, Serial and Optional Ethernet Interface Capabilities</li>
<li>10-year Battery Life</li>
<li>Alarm Output</li>
<li><strong>SiteView software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/vl-rtd-1-rtd-data-logger/">VersaLog VL-RTD-1</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>The VersaLog VL-RTD-1 RTD Temperature Data Logger</h3>
<p>The VersaLog VL-RTD-1 RTD Data Logger is a 4-channel, battery-powered, standalone temperature data logger.  It records the ambient temperature with a built-in thermistor and has four external 2 or 3 wire RTD inputs plus alarm output capabilities. Data is stored in 8 MB of non-volatile flash memory for later retrieval.</p>
<p>The VL-RTD-1 is a high accuracy device, its 4 external RTD channels offer accuracy of +/-0.16°C @ 25°C. It accepts standard 2 or 3 wire PT-100 RTD probes that have a resistance value of 100 ohms at 25°C. It is powered by a 16-bit ADC and is well suited to science and laboratory applications where precise and accurate measurement is critical.</p>
<p>The VL-RTD-1 RTD data logger features an aluminum enclosure and provides excellent performance in the harshest industrial environments. It has both USB and serial interfaces and can connect to Ethernet networks using the optional <a href="https://dataloggerinc.com/product/dss-2-usb-device-server/">DSS-2</a> device server.  The VL-RTD-1 is powered by an internal non-rechargeable lithium battery with up to 10-year life.</p>
<h3>Memory Capacity</h3>
<hr />
<p>All VersaLog data loggers come with 8MB onboard flash memory. The following table shows the relationship between the number of enabled channels, sampling interval, and max time span of logging.</p>
<table border="1" width="66%">
<tbody>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Sampling Interval</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Number of Channels</strong></td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;"><strong>Logging Capacity</strong></td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">7.96 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">3.98 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 min</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">362 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1.33 years</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">242 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">10 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">60 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">48 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">24 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1 sec</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">6 days</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">1</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">116 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">2</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">58 hours</td>
</tr>
<tr>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">100 milliseconds</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">8</td>
<td style="vertical-align: middle; text-align: left; padding: 3px; background-color: #e8eef7; border: 2px solid white;">14.4 hours</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://dataloggerinc.com/product/vl-rtd-1-rtd-data-logger/">VersaLog VL-RTD-1</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Loggito WiFi Logger</title>
		<link>https://dataloggerinc.com/product/loggito-wifi-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 20:20:46 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=16241</guid>

					<description><![CDATA[<h2>4/8 Channel Data Logger with WiFi</h2>
<ul>
<li>4 or 8 Universal analog inputs (mV, mA, TC, RTD)</li>
<li>2 to 8 Digital inputs and digital outputs</li>
<li>WiFi and USB communications interfaces</li>
<li>Up to 16 GB of local storage</li>
<li>Sample rate up to 500 Hz</li>
<li>Expandable</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/loggito-wifi-data-logger/">Delphin Loggito WiFi Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Loggito WiFi Data Logger by Delphin proves that good things do indeed come in small packages! It is excellent for distributed monitoring systems, data acquisition with a low number of channels, and other low-power applications in a wide variety of industries. The Loggito can be used as a central data processing/data storage unit or it can be equipped with a card to provide 4 or 8 universal analog inputs for mV, mA, thermocouples, or RTDs (-R model cards). Additional digital I/O cards are also available to provide up to 8 digital inputs/outputs.</p>
<p>The Loggito WiFi Logger module can be used connected to a PC or equipped with internal data storage to create a stand-alone system for data acquisition or data logging. It can be used with conventional software channels, which means that it can internally pre-process and calculate measurement channels. The module can also act as the coordinator for your measurement network and is the interface to the ProfiSignal data acquisition software and ProfiSignal Web browser-based monitoring software.</p>
<p><a href="https://dataloggerinc.com/products/manufacturer/delphin-technology/">View more Delphin Technology products</a></p>
<p>The post <a href="https://dataloggerinc.com/product/loggito-wifi-data-logger/">Delphin Loggito WiFi Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Loggito LAN Logger</title>
		<link>https://dataloggerinc.com/product/loggito-lan-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 08 Mar 2018 19:57:52 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=16198</guid>

					<description><![CDATA[<h2>4/8 Channel Data Logger with Ethernet Interface</h2>
<ul>
<li>4 or 8 Universal analog inputs (mV, mA, TC, RTD)</li>
<li>2 to 8 Digital inputs and digital outputs</li>
<li>LAN and USB communications interfaces</li>
<li>Up to 16 GB of local storage</li>
<li>Sample rate up to 500 Hz</li>
<li>Expandable</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/loggito-lan-data-logger/">Delphin Loggito LAN Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Loggito LAN Data Logger by Delphin proves that good things do indeed come in small packages! The Loggito is excellent for distributed monitoring systems, data acquisition with a low number of channels, and other low-power applications in a wide variety of industries. The Loggito can be used as a central data processing/data storage unit or it can be equipped with a card to provide 4 or 8 universal analog inputs for mV, mA, thermocouples, or RTD&#8217;s (-R model cards). Additional digital I/O cards are also available to provide up to 8 digital inputs/outputs.</p>
<p>The Loggito LAN Logger module can be used connected to a PC or equipped with internal data storage to create a stand-alone system for data acquisition or data logging. It can be used with conventional software channels, which means that it can internally pre-process and calculate measurement channels. The module can also act as the coordinator for your measurement network and is the interface to the ProfiSignal data acquisition software and ProfiSignal Web browser-based monitoring software.</p>
<p><a href="https://dataloggerinc.com/products/manufacturer/delphin-technology/">View more Delphin Technology products</a></p>
<p>The post <a href="https://dataloggerinc.com/product/loggito-lan-data-logger/">Delphin Loggito LAN Logger</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>dataTaker DT80GW</title>
		<link>https://dataloggerinc.com/product/dt80gw-wifi-geotechnical-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 29 Jun 2017 22:15:12 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=9101</guid>

					<description><![CDATA[<h2>5-Channel Geotechnical Data Logger with WiFi</h2>
<ul>
<li>Vibrating Wire Sensor Support</li>
<li>Carlson, Electro Level &#38; LVDT support</li>
<li>Up to 15 Analog (± 50V) sensor inputs</li>
<li>Expandable to 300 analog inputs</li>
<li>Programmable Analog Output</li>
<li>Integrated Wi-Fi</li>
<li>Automatic data transfer via email or FTP</li>
<li>Modbus for SCADA connection</li>
<li>USB memory for easy data and program transfer</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dt80gw-wifi-geotechnical-data-logger/">dataTaker DT80GW</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>DT80GW WiFi Geotechnical Data Logger</h2>
<p>Advanced design and technology plus 25 years of geotechnical expertise have produced the dataTaker DT80GW WiFi Geotechnical Data Logger – A versatile, powerful – yet low-power &amp; cost-effective logger.</p>
<p>It supports vibrating wire and other geotechnical sensors such as Slope Indicator, RST Instruments, Geokon, Soil Instruments, Roctest, AGI – Applied Geomechanics Inc. DT80GW is also capable of testing sensor integrity through audible frequency</p>
<p>With temperature compensation (thermistor), 5 analog channels are capable of reading up to 5 vibrating wire sensors. If temperature compensation is not required this logger can read up to 15 vibrating wire sensors.</p>
<p>Further expansion up to 100 sensors (with temperature compensation) or 300 sensors(without temperature compensation) is possible.</p>
<h3>Local Wireless Access</h3>
<p>With wireless access, no need to have a physical connection to the logger. Send the program, view and download the data, or even modify your settings on a nearby PC or Tablet wirelessly either as a Master (Access Point mode) or Slave (Client).</p>
<h3>Automatic Data Delivery</h3>
<p>On Client mode, dataTaker can have access to a local router and if the router has internet access it can utilize the DT80GW’s automatic data delivery features to schedule your data to be automatically emailed to your inbox every day, week, month, or other time interval.</p>
<p>More sophisticated systems can make use of the automatic data delivery features to send logged data to an FTP server.</p>
<h3>Superior Data Storage &amp; Communications</h3>
<p>With the standard unit able to store up to 10 million data points (expandable) you can log as much or as little as you need. Overwrite or stop logging once allocated memory is full, archive data on alarm event, copy to USB memory or transfer via FTP/ Email, the choice is yours.</p>
<p>Communications features include RS232, USB, and Ethernet, which connect to the DT80GW locally, remotely through a modem, or over the Internet.</p>
<p>The post <a href="https://dataloggerinc.com/product/dt80gw-wifi-geotechnical-data-logger/">dataTaker DT80GW</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>dataTaker DT80W</title>
		<link>https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 29 Jun 2017 20:53:03 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=9097</guid>

					<description><![CDATA[<h2>5 Channel Universal Input Data Logger with WiFi</h2>
<ul>
<li>Up to 15 Analog (± 50V) sensor inputs</li>
<li>Expandable to 300 analog inputs</li>
<li>12 flexible digital terminals</li>
<li>2 Serial ‘Smart Sensor’ ports</li>
<li>SDI-12 (multiple networks)</li>
<li>Programmable Analog Output</li>
<li>Integrated WiFi</li>
<li>Automatic data transfer via email or FTP</li>
<li>Sending alarm via SMS or email</li>
<li>Modbus for SCADA connection</li>
<li>USB memory for easy data and program transfer</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/">dataTaker DT80W</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>DT80W Universal Input Data Logger with Integrated WiFi</h2>
<h3>Versatile Measurement</h3>
<p>The DT80W WiFi Universal Input Data Logger allows you to connect an array of sensors through versatile analog and digital channels, high-speed counter inputs, phase encoder inputs, and programmable serial sensor channels.</p>
<p>Temperature, voltage, current, 4-20mA loops, resistance, bridges, strain gauges, frequency, digital, serial, and calculated measurements can all be scaled, logged, and returned in engineering units or within statistical reporting.</p>
<p>Set up sampling, logging, alarm, and control tasks to suit your requirements while interfaces for smart sensors, GPS, and other intelligent devices expand the dataTaker DT80W flexibility.</p>
<h3>Local Wireless Access</h3>
<p>With wireless access, no need to have a physical connection to the logger. Send the program, view and download the data, or even modify your settings on a nearby PC or Tablet wirelessly either as a Master (Access Point mode) or Slave (Client).</p>
<h3>Automatic Data Delivery</h3>
<p>On Client mode, dataTaker can have access to a local router and if the router has internet access it can utilize the DT80W’s automatic data delivery features to schedule your data to be automatically emailed to your inbox every day, week, month, or other time interval.</p>
<p>More sophisticated systems can make use of the automatic data delivery features to send logged data to an FTP server.</p>
<p>The post <a href="https://dataloggerinc.com/product/dt80w-wifi-universal-input-data-logger/">dataTaker DT80W</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VersaLog VL-BR</title>
		<link>https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Thu, 27 Oct 2016 22:31:33 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=4634</guid>

					<description><![CDATA[<ul>
<li>The 16-bit analog-to-digital converter meets most high-resolution requirements</li>
<li>The 4 MB Memory stores up to 2 million measurements</li>
<li>2.5V excitation with compensation</li>
<li>± 8 mV input range</li>
<li>Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps</li>
<li>10-year battery life</li>
<li>Fast sampling mode</li>
<li>Alarm and excitation output</li>
<li><strong>Siteview software required (1 license per site) and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/">VersaLog VL-BR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The VL-BR Strain Gauge Bridge Data Logger is a single channel, battery powered, stand-alone strain gauge bridge data logger. It supports one 4/6 wire Wheatstone bridge by providing voltage excitation, excitation voltage compensation, and low-level signal amplification. Data is stored in nonvolatile flash memory for later retrieval.</p>
<p>The VL-BR Strain Gauge Bridge Data Logger features a measurement input voltage range of -8 mV to +8 mV to accommodate most common bridges with a sensitivity of up to 3 mV/V.</p>
<p>Featuring an aluminum enclosure and PCB coating, the logger has excellent performance in the harshest industrial environment.</p>
<p>Powered by 16-bit ADC and programmable input range, the logger is well suited to science and laboratory applications where precise and accurate measurement is critical.</p>
<p><a href="/product/siteview-software/">Siteview software</a> is required and sold separately. One license per site, can be used on multiple loggers.</p>
<p>The post <a href="https://dataloggerinc.com/product/vl-br-strain-gauge-bridge-data-logger/">VersaLog VL-BR</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Delphin Expert Logger 400</title>
		<link>https://dataloggerinc.com/product/expert-logger-400/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 11 Oct 2016 19:10:04 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/expert-logger-400/</guid>

					<description><![CDATA[<h2>16 Channel Data Logger</h2>
<ul>
<li>16 Universal analog inputs (mV mA, TC, RTD)</li>
<li>Sampling rate 1000 m/sec</li>
<li>24 Digital inputs / outputs</li>
<li>6 Analog outputs</li>
<li>32 Gb Internal Storage</li>
<li><strong>Software required and sold separately</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-400/">Delphin Expert Logger 400</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Expert Logger 400 Data Acquisition System</h2>
<p>The Expert Logger 400 is Delphin‘s new generation of data loggers. It combines the latest communication technology with advanced measurement technology and is based on FPGA technology to make it especially powerful. It can process up to 16 analog input channels at both low and high rates of sampling. Measurement data can be accurately acquired, independently stored and transmitted to the internet or a PC for evaluation via USB, LAN, WLAN or LTE.</p>
<h3>Operation Made Simple</h3>
<p>Sensors are connected via plug-in screw terminals and a chart clearly shows how channels are arranged. Users always have a good overview of the channels despite their high density. Each set of four terminals can be configured as two differential inputs to measure voltage, currents, thermocouples, or to take measurements from a 4-wire RTD.</p>
<h3>Configuration &#8211; Fast and Easy</h3>
<p>The Expert Logger 400 is simple to configure from a PC. These settings remain stored within the Expert Logger even when disconnected from the power supply. The device settings can also be read out and stored on a PC and analyzed offline without the need for a connected Expert Logger. The offline configuration settings are then simply read into the device when connected. The software used for configuration is simple to operate to let users fully focus on their measurement tasks.</p>
<h3>Intelligent Signal Processing</h3>
<p>Signal processing using internal software channels significantly simplifies measurement tasks. Flexible calculation channels enable measurement data to undergo further computation and recording. Integrators directly calculate volumes or quantities from time-related measurement data such as mass and discharge flow rates. Limit values can monitor measurement data and be used to switch digital outputs or automatically send emails. Complex signal processing is possible using pulse counters, stop-clock functions, and operating-hours counter. Averages can be calculated and recorded as time-weighted or moving. The Expert Logger‘s software channels clearly set it apart from other loggers and make it very popular among users.</p>
<h3>Applications</h3>
<ul>
<li>Data logging</li>
<li>Environmental measurement technology</li>
<li>Product testing</li>
<li>Measurement data diagnosis</li>
<li>Lab data acquisition</li>
<li>Trials and tests</li>
<li>Energy optimization</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/expert-logger-400/">Delphin Expert Logger 400</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
