<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Current Data Loggers for Any Application - CAS DataLoggers</title>
	<atom:link href="https://dataloggerinc.com/products/current-data-loggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://dataloggerinc.com/products/current-data-loggers/</link>
	<description>Data logger and data acquisition products for any application.</description>
	<lastBuildDate>Mon, 23 Mar 2026 18:36:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dataloggerinc.com/wp-content/uploads/2017/11/cropped-logo-larger-1-32x32.jpg</url>
	<title>Current Data Loggers for Any Application - CAS DataLoggers</title>
	<link>https://dataloggerinc.com/products/current-data-loggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AEMC PEL 115</title>
		<link>https://dataloggerinc.com/product/aemc-pel-115/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 08 Apr 2025 19:23:10 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995401</guid>

					<description><![CDATA[<ul>
<li>4 Voltage Inputs and 4 Current Inputs</li>
<li>Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations</li>
<li>Powered by the phase – 1,000 V AC/DC</li>
<li>8GB Data Storage on SD Card (up to 32GB on SD-HC Card)</li>
<li>USB, Ethernet RJ45, or Wi-Fi (server) Communication</li>
<li>Quadruple digital display</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-115/">AEMC PEL 115</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PEL 115 measures and records all the power and energy values. Delivered in an IP67 site-proof case, the PEL 115 is ideal for use in the field or outdoors in multiple sectors:<br />
• electricity generator: renewable energies, thermal energy, etc.<br />
• industries: metallurgy, glassmaking, agri-food<br />
• residential buildings, tertiary, etc.<br />
• infrastructure and transport</p>
<p><strong>Applications</strong><br />
• Energy audits<br />
• Electrical diagnostics<br />
• Industrial maintenance<br />
• Simple, effective ergonomics<br />
In its site-proof case with the mounting kit, it can be installed very easily at the top of an electricity pole. The large backlit display is easy to read in all circumstances. It is equipped with 1 voltage inputs and 4 current inputs.</p>
<p><strong>RMS and DC measurements</strong><br />
• AC and/or DC voltages up to 1,000 V<br />
• currents up to 10 kA AC or 5 kA DC (depending on the current sensor).<br />
• active, reactive and apparent power values<br />
• active, reactive and apparent energy values<br />
• fundamental and balanced active power values and unbalanced active power values<br />
• measurements and characterization on motors (via Android application)<br />
• breakdown of energy losses<br />
• phase information: cos φ, tan Φ, power factor (PF)<br />
• crest factor<br />
• THD calculation for currents and voltages<br />
• DC, 50 Hz, 60 Hz and 400 Hz (Naval, etc.) measurements</p>
<p><strong>PEL Transfer software</strong><br />
With the PEL Transfer software you can:<br />
• set up your PEL<br />
• check the connections before recording begins<br />
• download the measurements recorded in the PEL<br />
• view the results of the various measurements and analyses<br />
Additional advantage: PEL Transfer converts your electricity consumption into the local currency (€, £, $, etc. &#8211; 8 tariff ranges).</p>
<p><strong>Communication and networks</strong><br />
The PEL 110 models offer multiple communication modes:<br />
&#8211; USB , the simplest link when not working remotely<br />
&#8211; Ethernet RJ45 or Wi-fi (server): connect your PEL11x to the server to communicate from any workstation in the network equipped with the PEL Transfer software<br />
&#8211; Wi-fi (Access Point):<br />
• Create a direct link between the PEL11x and your computer<br />
• The Access Point (AP) mode supports up to 5 clients</p>
<p>A PEL 115 IS DELIVERED WITH 1 bag for the accessories, 5 x IP67 voltage cables, 5 lockable crocodile clips, 1 set of inserts/rings, 1 SD card, 1 SD Card-USB adapter, 1 USB cable, PEL TRANSFER PC software &amp; User’s Manual downloadable from our website, 1 Quick Start Guide.</p>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-115/">AEMC PEL 115</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC PEL 112</title>
		<link>https://dataloggerinc.com/product/aemc-pel-112/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 08 Apr 2025 19:17:52 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995400</guid>

					<description><![CDATA[<ul>
<li>3 Voltage Inputs and 3 Current Inputs</li>
<li>Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations</li>
<li>Ideal for use in cold rooms (-20 °C)</li>
<li>8GB Data Storage on SD Card (up to 32GB on SD-HC Card)</li>
<li>Compact and Magnetized</li>
<li>USB, Ethernet RJ45, or Wi-Fi (server) Communication</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-112/">AEMC PEL 112</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PEL 112 measures and records all the power and energy values.<br />
It can be used wherever there is electricity:<br />
• electricity generator: renewable energies, thermal energy, etc.<br />
• industries: metallurgy, glassmaking, agri-food<br />
• residential buildings, tertiary, etc.<br />
• infrastructure and transport<br />
• datacenters, etc.</p>
<p><strong>Applications</strong><br />
• Energy audits<br />
• Electrical diagnostics<br />
• Industrial maintenance</p>
<p><strong>Simple, Effective Ergonomics</strong><br />
• compact and magnetized<br />
• 3 voltage inputs and 3 current inputs<br />
• ideal for use in cold rooms (-20 °C)<br />
• self-powered via the phase (option)</p>
<p><strong>RMS and DC Measurements</strong><br />
• AC and/or DC voltages up to 1,000 V<br />
• currents up to 10 kA AC or 5 kA DC (depending on the current sensor).<br />
• active, reactive and apparent power values<br />
• active, reactive and apparent energy values<br />
• fundamental and balanced active power values and unbalanced active power values<br />
• measurements and characterization on motors (via Android application)</p>
<p><strong>Functions</strong><br />
• breakdown of energy losses<br />
• phase information: cos φ, tan Φ, power factor (PF)<br />
• crest factor<br />
• THD calculation for currents and voltages<br />
• DC, 50 Hz, 60 Hz and 400 Hz (Naval, etc.) measurements</p>
<p><strong>PEL Transfer software</strong><br />
With the PEL Transfer software you can:<br />
• set up your PEL<br />
• check the connections before recording begins<br />
• download the measurements recorded in the PEL<br />
• view the results of the various measurements and analyses<br />
Additional advantage: PEL Transfer converts your electricity consumption into the local currency (€, £, $, etc. &#8211; 8 tariff ranges).</p>
<p><strong>Communication and Networks</strong><br />
The PEL 110 models offer multiple communication modes:<br />
&#8211; USB , the simplest link when not working remotely<br />
&#8211; Ethernet RJ45 or Wifi (server): connect your PEL11x to the server to communicate from any workstation in the network equipped with the PEL Transfer software<br />
&#8211; Wifi (Access Point):<br />
• Create a direct link between the PEL11x and your computer<br />
• The Access Point (AP) mode supports up to 5 clients</p>
<p>A PEL 112 IS DELIVERED WITH: 1 carrying bag, 4 voltage cables, 4 crocodile clips, 1 set of inserts/ rings, 1 SD card, 1 SD Card-USB adapter, 1 USB cable, PEL TRANSFER PC software &amp; User’s Manual downloadable from our website, 1 Quick Start Guide.</p>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-112/">AEMC PEL 112</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC PEL 113</title>
		<link>https://dataloggerinc.com/product/aemc-pel-113/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 08 Apr 2025 18:53:10 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=995399</guid>

					<description><![CDATA[<ul>
<li>3 Voltage Inputs and 3 Current Inputs</li>
<li>Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations</li>
<li>8GB Data Storage on SD Card (up to 32GB on SD-HC Card)</li>
<li>Compact and Magnetized</li>
<li>USB, Ethernet RJ45, or Wi-Fi (server) Communication</li>
<li>Quadruple digital display</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-113/">AEMC PEL 113</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PEL 113 measures and records all the power and energy values.<br />
It can be used wherever there is electricity:<br />
• electricity generator: renewable energies, thermal energy, etc.<br />
• industries: metallurgy, glassmaking, agri-food<br />
• residential buildings, tertiary, etc.<br />
• infrastructure and transport<br />
• datacenters, etc.<br />
<strong>Applications</strong><br />
• Energy audits<br />
• Electrical diagnostics<br />
• Industrial maintenance<br />
<strong>Simple, effective ergonomics</strong><br />
• compact and magnetized<br />
• 3 voltage inputs and 3 current inputs<br />
• quadruple backlit digital display<br />
• self-powered via the phase<br />
<strong>RMS and DC measurements</strong><br />
• AC and/or DC voltages up to 1,000 V<br />
• currents up to 10 kA AC or 5 kA DC (depending on the current sensor).<br />
• active, reactive, and apparent power values<br />
• active, reactive, and apparent energy values<br />
• fundamental and balanced active power values and unbalanced active power values<br />
• measurements and characterization on motors (via Android application)<br />
<strong>Functions</strong><br />
• breakdown of energy losses<br />
• phase information: cos φ, tan Φ, power factor (PF)<br />
• crest factor<br />
• THD calculation for currents and voltages<br />
• DC, 50 Hz, 60 Hz, and 400 Hz (Naval, etc.) measurements<br />
<strong>PEL Transfer software</strong><br />
With the PEL Transfer software you can:<br />
• set up your PEL<br />
• check the connections before recording begins<br />
• download the measurements recorded in the PEL<br />
• view the results of the various measurements and analyses<br />
Additional advantage: PEL Transfer converts your electricity consumption into the local currency (€, £, $, etc. &#8211; 8 tariff ranges).</p>
<p><strong>Communication and networks</strong><br />
The PEL 110 models offer multiple communication modes:<br />
&#8211; USB, the simplest link when not working remotely<br />
&#8211; Ethernet RJ45 or Wi-fi (server): connect your PEL11x to the server to communicate from any workstation in the network equipped with the PEL Transfer software<br />
&#8211; Wi-fi (Access Point):<br />
• Create a direct link between the PEL11x and your computer<br />
• The Access Point (AP) mode supports up to 5 clients</p>
<p>A PEL 113 IS DELIVERED WITH: 1 carrying bag, 4 voltage cables, 4 crocodile clips, 1 set of inserts/ rings, 1 SD card, 1 SD Card-USB adapter, 1 USB cable, PEL TRANSFER PC software &amp; User’s Manual downloadable from our website, 1 Quick Start Guide.</p>
<p>The post <a href="https://dataloggerinc.com/product/aemc-pel-113/">AEMC PEL 113</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder AL-2VA</title>
		<link>https://dataloggerinc.com/product/electrocorder-al-2va/</link>
					<comments>https://dataloggerinc.com/product/electrocorder-al-2va/#respond</comments>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Tue, 02 Jul 2024 14:43:12 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=992894</guid>

					<description><![CDATA[<ul>
<li>One voltage channel 300Vac, One current channel up to 15Aac</li>
<li>Enables voltage and load problems to be highlighted for further investigation.</li>
<li>Voltage channels record VAvg, VMax &#38; VMin.</li>
<li>Recorded data is uploaded via USB to a PC for analysis with Free Electrosoft Software.</li>
<li>Data is stored in non-volatile memory.  Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording.</li>
<li>Kit includes logger, mains socket, USB lead, Electrosoft software, and carry case.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/electrocorder-al-2va/">Electrocorder AL-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>AL-2VA Single Phase Energy/Power Logger</h3>
<p>The AL-2VA is designed to allow users to monitor one voltage channel and one current channel. Allowing users to monitor the main voltage supply and the load current, therefore enabling staff to determine the energy consumption of various appliances or items of equipment.</p>
<p>Setting up the Electrocorder AL-2VA is easy, making it suitable for non-technical staff. Using the supplied (free) Windows software, Electrosoft; input the location details for the logging and choose the logging period. Electrosoft will print the necessary dispatch/ return documentation including user instructions. All data is included in a database of dispatches and returns, allowing you to track the location of multiple loggers.</p>
<p>Why is the Electrocorder better than other similarly priced competitors? The Electrocorder range uses a constant sampling technique, unlike the single reading of competitors. When the loggers start to record, they sample every channel 16 times per cycle, a cycle is 16ms at 60Hz. At the end of each averaging period, 3 quantities are saved for each channel, the True RMS average, the Max, which is the highest cycle value during the period, and the Min, the lowest cycle value. This means that it will record all the peaks and troughs which are one cycle or longer. The voltage and current levels are stored with dates and times. With the backup battery, the logger can continue to record for months. On the logger, data recording is signified by a flashing green light. A red light advises users that the unit has completed recording.</p>
<p>When the logger has finished recording, the stored data is uploaded to a PC via the supplied USB cable. Using Electrosoft, the recorded voltage and current levels have dates and times that can be viewed in both tabular and graphical form, exported to a spreadsheet, or saved to a file. Graphs can be printed showing the recorded levels and the allowable tolerance bands. Electrosoft also provides an internal database that effectively manages the distribution of multiple loggers.</p>
<p>&nbsp;</p>
<p>The post <a href="https://dataloggerinc.com/product/electrocorder-al-2va/">Electrocorder AL-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dataloggerinc.com/product/electrocorder-al-2va/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AEMC DL913</title>
		<link>https://dataloggerinc.com/product/aemc-dl913/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 01 Feb 2023 18:47:24 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com//?post_type=product&#038;p=988070</guid>

					<description><![CDATA[<ul>
<li>3 channel AC current</li>
<li>3 integral 24-inch flexible current sensors</li>
<li>Current measurements from 500 mA up to 3600 A</li>
<li>LCD display to view real-time measurements and parameters, configure the instrument, and change viewing modes</li>
<li>Built-in web server for remote monitoring</li>
<li>Battery and/or USB-powered options</li>
<li>Wi-Fi and USB communications</li>
<li>Waterproof IP67 rated (USB cap on and the cover closed)</li>
<li>Flame retardant case</li>
<li>Logged data can be downloaded, analyzed, and formatted into reports using the FREE DataView® software</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/aemc-dl913/">AEMC DL913</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>AEMC DL913 AC Current Data Logger</h3>
<p>The AEMC DL913 AC Current Data Logger is a 3-channel AC current data logger with three integral flexible current sensors. Each sensor is 24 inches long and capable of wrapping around a 7.64-inch conductor. The DL913 has two measurement ranges of up to 300 and 3000 Amps. Both the data logger housing and the current sensors are water resistant and rated to IP 67. A selection of data storage modes, as well as data sampling rates, is user programmable through the DataView<sup>®</sup> software included with the unit. However, most of the setup can also be done from the keypad and LCD display on the instrument. The measurements are stored in internal nonvolatile memory. Data storage rates as fast as once per second.</p>
<p>Communication is done through a USB port or wireless Wi-Fi and it is powered by two rechargeable NiMH batteries. The instrument can also be externally powered through the USB plug.</p>
<p>Includes small classic tool bag, 10 ft USB Type A to Type B cable, (4) stainless steel mounting brackets with (4) Phillips M4-0.7 x 8 mm stainless steel machine screws, USB power adapter, quick start guide, and USB thumb drive with DataView® software and user manual.</p>
<h4>Applications</h4>
<ul>
<li>Single/Split-phase and 3- or 4-phase load monitoring</li>
<li>Neutral and ground current monitoring</li>
<li>Intermittent problem detection</li>
<li>Machine load monitoring</li>
<li>Fault current detection</li>
<li>Load profiling</li>
</ul>
<p><iframe title="YouTube video player" src="https://www.youtube.com/embed/XqyIRxVGCM4" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The <a href="https://dataloggerinc.com/product/aemc-dl914/" target="_blank" rel="noopener">DL914</a> is also available with an added channel for neutral current monitoring</p>
<p>The post <a href="https://dataloggerinc.com/product/aemc-dl913/">AEMC DL913</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC DL914</title>
		<link>https://dataloggerinc.com/product/aemc-dl914/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 01 Feb 2023 18:47:22 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com//?post_type=product&#038;p=988069</guid>

					<description><![CDATA[<ul>
<li>3 channel AC current</li>
<li>1 channel for neutral current monitoring</li>
<li>4 integral 24-inch flexible current sensors</li>
<li>Current measurements from 500 mA up to 3600 A</li>
<li>LCD display to view real-time measurements and parameters, configure the instrument, and change viewing modes</li>
<li>Built-in web server for remote monitoring</li>
<li>Battery and/or USB-powered options</li>
<li>Wi-Fi and USB communications</li>
<li>Waterproof IP67 rated (with USB cap on and the cover closed)</li>
<li>Flame retardant case</li>
<li>Logged data can be downloaded, analyzed, and formatted into reports using the FREE DataView® software</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/aemc-dl914/">AEMC DL914</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>AEMC DL914 AC Current Data Logger</h3>
<p>The AEMC DL914 AC Current Data Logger is a 4-channel AC current data logger with four integral flexible current sensors. Each sensor is 24 inches long and capable of wrapping around a 7.64-inch conductor. The DL914 has two measurement ranges of up to 300 and 3000 Amps. Both the data logger housing and the current sensors are water resistant and rated to IP 67. A selection of data storage modes, as well as data sampling rates, is user programmable through the DataView<sup>®</sup> software included with the unit. However, most of the setup can also be done from the keypad and LCD display on the instrument. The measurements are stored in internal nonvolatile memory. Data storage rates as fast as once per second.</p>
<p>Communication is done through a USB port or wireless Wi-Fi and it is powered by two rechargeable NiMH batteries. The instrument can also be externally powered through the USB plug.</p>
<p>Includes small classic tool bag, 10 ft USB Type A to Type B cable, (4) stainless steel mounting brackets with (4) Phillips M4-0.7 x 8 mm stainless steel machine screws, USB power adapter, quick start guide, and USB thumb drive with DataView® software and user manual.</p>
<h4>Applications:</h4>
<ul>
<li>Single/Split-phase and 3- or 4-phase load monitoring</li>
<li>Neutral and ground current monitoring</li>
<li>Intermittent problem detection</li>
<li>Machine load monitoring</li>
<li>Fault current detection</li>
<li>Load profiling</li>
</ul>
<p><iframe title="YouTube video player" src="https://www.youtube.com/embed/XqyIRxVGCM4" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<p>The <a href="https://dataloggerinc.com/product/aemc-dl913/" target="_blank" rel="noopener">DL913</a> is also available if you only require 3 channels</p>
<p>The post <a href="https://dataloggerinc.com/product/aemc-dl914/">AEMC DL914</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>TandD RTR-505B-mA</title>
		<link>https://dataloggerinc.com/product/tandd-rtr-505b-ma/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 15 Jan 2021 19:32:54 +0000</pubDate>
				<guid isPermaLink="false">http://101906d585.nxcli.net/?post_type=product&#038;p=528822</guid>

					<description><![CDATA[<ul>
<li>Measures 0 to 20mA (Operational up to 40mA)</li>
<li>Recording modes: instantaneous or average</li>
<li>Logging capacity: 16,000 readings</li>
<li>Wireless communication range of up to 150 meters (500 feet)</li>
<li>Battery life of about 10 months</li>
<li>Data can be collected remotely via: USB, GSM technology, LAN and handheld data collectors</li>
<li>WebStorage Service available</li>
<li><strong>Additional Base Station required for communication<br />
</strong></li>
<li><strong>A 9.5% Tariff Surcharge will be added to this item at checkout</strong></li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/tandd-rtr-505b-ma/">TandD RTR-505B-mA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>TandD RTR-505B-mA Compact 4-20mA Current Data Logger</h2>
<p>The RTR-505B-mA is a current data logger with an included 4-20mA module that offers a  measurement range of 0 to 20mA and is operational up to 40mA. The logger offers either an instantaneous or average recording mode.</p>
<p>The brand new RTR-500B series allows you to mix and match an array of wireless radio communication loggers with various Base Units or Data Collectors to meet your needs. Logged data can be automatically sent via network or mobile communication to be saved in <a title="T&amp;D WebStorage Service" href="https://webstorage-service.com/" target="_blank" rel="noopener noreferrer">cloud storage</a> or to a specified location. This new generation adds BlueTooth 4.2 Low Energy communication as well as improved security.</p>
<p>RTR-505B-mA data loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).</p>
<p><img fetchpriority="high" decoding="async" class="alignleft wp-image-538354" src="https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-300x145.png" alt="" width="600" height="290" srcset="https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-300x145.png 300w, https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-1170x566.png 1170w, https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-768x371.png 768w, https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-1536x743.png 1536w, https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-2048x990.png 2048w, https://dataloggerinc.com/wp-content/uploads/2021/01/rtr505b-600x290.png 600w" sizes="(max-width: 600px) 100vw, 600px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on-site with one of our compatible data collectors. Data can be monitored in real-time and warning information can be viewed both on-site and from the cloud.</p>
<p>Looking for the RTR-505 versions? The <a href="https://dataloggerinc.com/products/tandd/rtr-wireless-data-loggers/" target="_blank" rel="noopener noreferrer">RTR-500 Series</a> has been effectively discontinued, however, existing RTR-500 Series hardware will work with the new RTR-500B Series.</p>
<h2>Introduction to the RTR-500B Series</h2>
<p><iframe loading="lazy" title="Introduction of the RTR500B Series" width="500" height="281" src="https://www.youtube.com/embed/8g-Vty_38JE?feature=oembed&#038;enablejsapi=1&#038;origin=https://dataloggerinc.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>The post <a href="https://dataloggerinc.com/product/tandd-rtr-505b-ma/">TandD RTR-505B-mA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC Powerpad III 8333</title>
		<link>https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 30 Nov 2016 23:32:38 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=5825</guid>

					<description><![CDATA[<ul>
<li>Measures TRMS Voltage up to 1000 Vrms AC or 1200 VDC for 1, 2 and 3-phase Systems</li>
<li>Measures TRMS Current up to 10 kArms (Sensor Dependent)</li>
<li>(4) Voltage Inputs and (3) Current Inputs</li>
<li>VA, var, W, kVAh, VARh, kWh and Totals (per Phase) Measurements and Recordings</li>
<li>Stores Trend Data, 4,000 Alarms, 51 Captured Transients and up to 12 Screen Snap Shots</li>
<li>Measures Harmonics for Voltage, Current or Power up to the 50th Harmonic</li>
<li>CE, Shock Resistant and Classified: IEC61000-4-30 Class B, IP50, 1000 V CAT III and 600 V CAT IV</li>
<li>USB Communication Interface</li>
<li>LCD Display Shows Real-time Waveforms and Trend Data</li>
<li>Free DataView software included</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/">AEMC Powerpad III 8333</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Powerpad III 8333 Three Phase Power Quality Analyzer</h3>
<p>The AEMC Powerpad III 8333 Three Phase Power Quality Analyzer is an easy-to-use, compact and shock resistant three-phase power quality analyzer. It enables technicians and engineers to measure and carry out diagnostics and power quality work on single- or three-phase networks. Three current and four voltage input terminals are provided are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.</p>
<p>Model 8333 has memory available for storing trend data, alarms, transients, and snapshot data. Capable of storing up to 12 screen snapshots, up to 51 captured transients that contain four cycles for each active input, and 4,000 alarm events from up to 10 different parameters. Trend data can also be recorded for days, weeks or even months.</p>
<p><img loading="lazy" decoding="async" class="alignright wp-image-5822 size-full" title="AEMC 8336 Power Quality Analyzer Kit" src="https://dataloggerinc.com/wp-content/uploads/2016/11/8336-kit.jpg" alt="AEMC 8336 Power Quality Analyzer Kit" width="200" height="120" /></p>
<p>Kit includes three MN193 current probes, four black 10 ft voltage leads, four black alligator clips, twelve color-coded input ID markers, NiMH battery, 110/240V power adapter with USB stick supplied with product user manual and DataView software.</p>
<p>Applications include:</p>
<ul>
<li>Verification of power distribution circuits</li>
<li>In-plant troubleshooting of power distribution panels and individual machinery</li>
<li>Monitor pad mount transformers and phase unbalances</li>
<li>Determine harmonic problems originating from source or load</li>
<li>Determine transformer K-Factor</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8333-three-phase-power-quality-analyzer/">AEMC Powerpad III 8333</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AEMC Powerpad III 8336</title>
		<link>https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Wed, 30 Nov 2016 21:47:39 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/?post_type=product&#038;p=5820</guid>

					<description><![CDATA[<ul>
<li>Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems</li>
<li>Measurement of TRMS currents up to 10,000Arms (sensor dependent)</li>
<li>Direct measurement of neutral current &#38; voltage</li>
<li>Frequency measurement (40 to 69Hz)</li>
<li>Record and display trend data as fast as once per second for one month for up to 41 variables</li>
<li>Transient detection on all V and I inputs (up to 210)</li>
<li>Measures harmonics for voltage, current or power up to the 50th harmonic</li>
<li>Recording, time stamping and characterization of disturbance</li>
<li>2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory</li>
<li>65µs/sample trend recording</li>
<li>Includes free DataView® software for configuring data storage, real-time display, analysis and report generation</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/">AEMC Powerpad III 8336</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignright wp-image-5822 size-full" title="AEMC 8336 Power Quality Analyzer Kit" src="https://dataloggerinc.com/wp-content/uploads/2016/11/8336-kit.jpg" alt="AEMC 8336 Power Quality Analyzer Kit" width="200" height="120" />The Powerpad III 8336 Three Phase Power Quality Analyzer from AEMC is an easy-to-use, compact and shock resistant data logger kit. Technicians and engineers can measure and carry out diagnostics and power quality work on one-, two- or three-phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV and 1000V CAT III.</p>
<p>The Powerpad III 8336 Three Phase Power Quality Analyzer has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. Capable of storing up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input or inrush data for up to 10 minutes, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.</p>
<p>Kit includes:</p>
<ul>
<li>5 black 10 ft voltage leads</li>
<li>5 black alligator clips</li>
<li>12 color-coded input ID markers</li>
<li>USB cable</li>
<li>NiMH battery</li>
<li>110/240V power adapter with US power cord</li>
<li>Toolbag</li>
<li>Soft carry pouch</li>
<li>User guide</li>
<li>USB stick supplied with product manual and DataView® software</li>
</ul>
<p>Applications include:</p>
<ul>
<li>Verification of power distribution circuits</li>
<li>In-plant troubleshooting of power distribution panels and individual machinery</li>
<li>Monitor pad mount transformers and phase unbalances</li>
<li>Determine harmonic problems originating from source or load</li>
<li>Determine transformer Factor-K</li>
<li>Energy metering (kVAh, VARh, kWh)</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/powerpad-iii-8336-three-phase-power-quality-analyzer/">AEMC Powerpad III 8336</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Electrocorder EC-2VA</title>
		<link>https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/</link>
		
		<dc:creator><![CDATA[Liz Zala]]></dc:creator>
		<pubDate>Fri, 23 Sep 2016 22:55:48 +0000</pubDate>
				<guid isPermaLink="false">https://dataloggerinc.com/product/ec-2va-single-phase-voltage-and-current-data-logger/</guid>

					<description><![CDATA[<ul>
<li>One voltage channel 300Vac, One current channel 300Aac</li>
<li>Enables voltage and load problems to be highlighted for further investigation.</li>
<li>One Voltage input (L1), one Current input (A1).</li>
<li>Voltage channels record VAvg, VMax &#38; VMin.</li>
<li>Recorded data is uploaded via USB to a PC for analysis with Free Electrosoft Software.</li>
<li>Data is stored in non-volatile memory.  Memory capacity of 32,000 (true RMS) values per channel (10bit), up to 300 days continuous recording.</li>
<li>Kit includes Logger, voltage input lead, Rogowski Coil, USB lead, software and carry case.</li>
</ul>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Single Phase EC-2VA AC Voltage Current Logger</h3>
<p>The EC-2VA AC Voltage Current Data Logger is specifically designed to monitor one voltage channel and one current. It allows you to monitor the main voltage supply and the load current, enabling staff to determine whether a voltage problem is load-related or not.</p>
<p>The Electrocorder range is designed to allow electrical distribution companies to cost-effectively monitor single and three-phase supplies. Our products allow voltage problems to be highlighted quickly for further investigation. The EC-2VA is designed to allow engineering staff to monitor single-phase voltage and current.</p>
<p>The voltage and current levels are stored with dates and times. With the backup battery, the Electrocorder can continue to record for a year. On the logger, the recording is signified by a flashing green light. A red light advises users that the unit has completed recording.</p>
<p>The post <a href="https://dataloggerinc.com/product/ec-2va-ac-voltage-current-data-logger/">Electrocorder EC-2VA</a> appeared first on <a href="https://dataloggerinc.com">CAS Dataloggers</a>.</p>
]]></content:encoded>
					
		
		