How to Connect Pressure Sensors to a Grant SQ2010 Data Logger

Grant SQ2010 Portable Universal Input Data Logger This article will explain how to connect pressure transducers and data loggers–specifically, transducers with an analog current signal (4-20ma), and the popular Grant Instruments SQ2010 portable universal input dataloggers. Required items for this project include a 2-wire pressure transducer with a 4-20ma signal; a 24V DC power supply, … Continued

Startup Process for the Accsense B1-06 Wireless Gateway

Cloud-Based Monitoring of Almost Any Parameter Gateway Startup Process: When users first connect an Accsense B1-06 wireless gateway to the network and power it up, it will go through the following process as it connects to the Acccsense server via the network: First the gateway will perform its Power On self-test. When this test is … Continued

Troubleshooting the Accsense A2-05 LAN-Wired Pod

No Blue Conn Light/Illuminated Stat1 Light If you’re having issues connecting your Accsense A2-05 LAN-Wired pod, this brief walkthrough from CAS DataLoggers should soon help you resolve the problem. You can also view ourYouTube video detailing this process at https://www.youtube.com/watch?v=2xBbOwtmQE4. Troubleshooting Issue: No Blue Conn Light When connecting the Accsense A2-05 LAN-Wired pod for the … Continued

Create a Time-Based Schedule Trigger With a dataTaker DT80

Based on the UNIX CRON Time Scheduler Version 9 firmware for the dataTaker DT80 datalogger includes a new time-based schedule trigger that is based on the UNIX CRON time scheduler. This powerful new schedule trigger type will greatly simplify many existing tasks and allow a greater flexibility in how and when a schedule is triggered. … Continued

Time-Synchronized Acquisition of GPS Positional Data

A Single System for Measurement and Analysis Delphin data loggers have the ability to determine positions via GPS signals. This is ideal for vehicular applications including automotive testing, flight testing, field trials and more. The GPS signal is received via a GPS sensor serially connected to a Delphin data logger. The sensor records GPS data … Continued

Non-SSL SMTP Servers for Use with dataTaker and Other Devices

Send Emails Through a dataTaker Data Logger Many standalone network devices that are able to e-mail, including data recorders and environmental monitors, cannot use SMTP servers that require SSL encryption. At CAS DataLoggers we’ve found a workaround for such problem and found other recording devices in the form of a free email service, and we’ll … Continued

Using a dataTaker DT80 with BrainChild IO-16DI Modules

Digital I/Os for Use with HMI, PLC or SCADA via Modbus RTU In our latest Technical Article adapted from dataTaker, CAS DataLoggers shows you how to use a dataTaker DT80 Intelligent Datalogger with a Brainchild Digital IO-16DI Module. This is useful for adding extra inputs for applications involving monitoring or controlling a PLC or SCADA … Continued

How to Calculate Covariance using a dataTaker

dataTaker Logger Performs Mathematical Calculations Covariance is a method of measuring how strongly variables are related to each other. Covariance is commonly used calculation used in a wide number of areas from microclimate flux and carbon sequestration, aquiculture, stock market predictions, to measurement of the southern oscillation index. In our latest Tech Article, CAS DataLoggers … Continued